Tehran University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
Feasibility of Improvement of the Filter Performance of Particle Filtering Respirators by Using Composite Media of Polyacrylonitrile Nanofiber (Pan) and Montmorillonite Clay Nanoparticles (Mmt)



Azad S1 ; Rashidi Y1 ; Golbabaei F2
Authors
Show Affiliations
Authors Affiliations
  1. 1. Department of Environmental Technologies, Environmental Sciences Research Institute, Shahid Beheshti University, Tehran, Iran
  2. 2. Department of Occupational Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran

Source: Journal of Health and Safety at Work Published:2023

Abstract

Introduction: The important parameters for evaluating the performance of particle filtering respirators in international standards are the filtration efficiency and respiratory resistance of the mask filter against airflow passage. To improve nanofiber filtration efficiency while creating the least breathing difficulty for the wearer, various research has been or is being conducted worldwide. This study investigated the effect of using polyacrylonitrile (PAN) nanofiber composite membrane and montmorillonite clay nanoparticles (MMT) in enhancing particle-filtering respirators' filter performance, achieving higher filtration efficiency while maintaining optimal respiratory resistance conditions. Material and Methods: First, PAN polymer solution containing zero, 1%, 2%, 3%, and 5% MMT nanoparticles was prepared, and then PAN/MMT nanofiber composite membrane was synthesized in an electrospinning machine. Filtration efficiency was measured in diameter range of 0.3, 0.5, 1, and 3 microns using sodium chloride aerosol. Additionally, filter breathing resistance was measured at flow rates of 30, 85, and 95 liters per minute. Results: The efficiency of synthesized composite nanofilters for particle purification can be improved by adding MMT nanoparticles to PAN nanofibers. Optimal MMT concentration was found to be 2%. This addition resulted in an increase in filtration efficiency for particles with sizes of 0.3, 0.5, 1, and 3 microns by 4.2%, 4.88%, 3.77%, and 2.75% respectively without causing significant difference in respiratory resistance. Improved filtration efficiency can be attributed to enhanced morphology of composite nanofilters resulting from addition of MMT nanoparticles. Adding 2% MMT nanoparticles to PAN nanofibers resulted in uniform distribution and smaller fiber dimensions which did not significantly affect Packing density and porosity. Conclusion: If 2% of MMT nanoparticles are added to PAN nanofibers and used to produce particle respirators, resulting respirator will exhibit a 4.2% increase in particle filtration efficiency without increasing breathing difficulty for user. This result can help protect users from particulate pollutants in air pollution conditions. © 2023, Tehran University of Medical Sciences. All rights reserved.