Tehran University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
Pneumocephalus After Orbital Decompression Surgery for Thyroid Eye Disease Publisher Pubmed



Ghahvehchian H1 ; Sadrhosseini S2 ; Fard M1
Authors
Show Affiliations
Authors Affiliations
  1. 1. Department of Ophthalmology, Farabi Eye Hospital, Tehran University of Medical Science, Tehran, 13366-16351, Iran
  2. 2. Department of Otolaryngology, Imam Khomeini Hospital, Tehran University of Medical Science, Tehran, Iran

Source: Middle East African Journal of Ophthalmology Published:2020


Abstract

A cerebrospinal fluid (CSF) leak is a rare complication after orbital surgery. We reported a 49-year-old man who presented with CSF leakage after transcaruncular medial wall decompression for proptosis due to thyroid eye disease. He underwent an endoscopic endonasal approach to surgical repair of the defect with nasoseptal flap. Rhinorrhea was stopped immediately after endoscopic repair. © 2020 Wolters Kluwer Medknow Publications. All rights reserved.