Tehran University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
Cardiac Resynchronization Therapy Device Implantation in a Patient With Congenitally Corrected Transposition of Great Vessels



Mollazadeh R1 ; Eslami M1
Authors
Show Affiliations
Authors Affiliations
  1. 1. Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran

Source: Journal of Tehran University Heart Center Published:2017

Abstract

A 29-year-old woman was referred to our hospital due to exacerbation in dyspnea on exertion and easy fatigability. A known case of congenitally corrected transposition of the great vessels and congenital complete heart block, she had already received a permanent single-chamber pacemaker. Decision was made to implant a biventricular pacemaker for the treatment of the failing heart. Excellent coronary sinus lead implantation was done, conferring amelioration of symptoms, QRS narrowing in the electrocardiogram, and improvement of systemic ventricular systolic function in echocardiography. Over a 15-month follow-up period, she had no dyspnea on exertion. This case highlights the significance of upgrading pacemakers in patients with heart failure. © 2017, Tehran Heart Center. All rights reserved.