Tehran University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
A New Linearly Constrained Minimum Variance Beamformer for Reconstructing Eeg Sparse Sources Publisher



Samadzadehaghdam N1, 2 ; Makkiabadi B1, 2 ; Masjoodi S1, 3 ; Mohammadi M1, 2 ; Mohagheghian F4
Authors
Show Affiliations
Authors Affiliations
  1. 1. Department of Medical Physics and Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences (TUMS), Tehran, Iran
  2. 2. Research Center for Biomedical Technology and Robotics (RCBTR), Institute of Advanced Medical Technologies (IAMT), Tehran University of Medical Sciences (TUMS), Tehran, Iran
  3. 3. Neuroimaging and Analysis Group (NIAG), Research Center for Molecular and Cellular Imaging (RCMCI), Tehran University of Medical Sciences, Tehran, Iran
  4. 4. Department of Medical Physics & Biomedical Engineering, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran

Source: International Journal of Imaging Systems and Technology Published:2019


Abstract

Brain source imaging based on EEG aims to reconstruct the neural activities producing the scalp potentials. This includes solving the forward and inverse problems. The aim of the inverse problem is to estimate the activity of the brain sources based on the measured data and leadfield matrix computed in the forward step. Spatial filtering, also known as beamforming, is an inverse method that reconstructs the time course of the source at a particular location by weighting and linearly combining the sensor data. In this paper, we considered a temporal assumption related to the time course of the source, namely sparsity, in the Linearly Constrained Minimum Variance (LCMV) beamformer. This assumption sounds reasonable since not all brain sources are active all the time such as epileptic spikes and also some experimental protocols such as electrical stimulations of a peripheral nerve can be sparse in time. Developing the sparse beamformer is done by incorporating L1-norm regularization of the beamformer output in the relevant cost function while obtaining the filter weights. We called this new beamformer SParse LCMV (SP-LCMV). We compared the performance of the SP-LCMV with that of LCMV for both superficial and deep sources with different amplitudes using synthetic EEG signals. Also, we compared them in localization and reconstruction of sources underlying electric median nerve stimulation. Results show that the proposed sparse beamformer can enhance reconstruction of sparse sources especially in the case of sources with high amplitude spikes. © 2019 Wiley Periodicals, Inc.
Experts (# of related papers)