Objective Measurement of Inferior-Directed Stiffness in Glenohumeral Joint Using a Specially Designed Robotic Device in Healthy Shoulders; Within- and Between-Session Reliability Publisher Pubmed



Azarsa MH1 ; Mirbagheri A1 ; Hosseini SR2 ; Shadmehr A3 ; Karimi N4
Authors
Show Affiliations
Authors Affiliations
  1. 1. Department of Medical Physics and Biomedical Engineering, School of Medicine and joint affiliated with Research Center for Biomedical Technologies and Robotics (RCBTR), Advanced Medical Technologies and Equipment Institute (AMTEI), Tehran University of Medical Sciences (TUMS), Tehran, Iran
  2. 2. School of Mechanical Engineering, Sharif University of Technology (SUT), Tehran, Iran
  3. 3. School of Rehabilitation, Tehran University of Medical Sciences (TUMS), Tehran, Iran
  4. 4. Department of Physiotherapy, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran

Source: Journal of Biomechanics Published:2021


Abstract

Clinical assessment of capsuloligamentous structures of the glenohumeral joint has been qualitative and subjective in nature, as demonstrated by limited intra- and inter-rater reliability. Robotic devices were utilized to develop a clinically objective measurement technique for glenohumeral joint stiffness. The purpose of this study was to quantify the amount of inferior-direction stiffness of the glenohumeral joint using a safe clinical device in the asymptomatic individuals, and to determine between trial and between session reliability of the robotic device. Twenty healthy subjects were recruited via convenience sampling. Inferior-directed translation and applying force were measured using displacement and force sensors of a robotic device. The stiffness values were calculated as the mean of the slopes of the linear portions of the force–displacement curves for the cycles obtained after familiarization and preconditioning. Four trials for each measurement occasion were averaged to determine the stiffness value for each subject in one session. Repeatability of glenohumeral joint stiffness measurements for between trials and between two sessions was determined using intraclass correlation values and standard error of the measurements. The mean stiffness value was 1.50 N/mm (±0.40) and 1.52 N/mm (±0.40), respectively. The robotic device for stiffness assessment was reliable for repeated measures of stiffness in one session, and between sessions with ICC equal 0.96 (95% CI 0.93–0.98), and 0.97 (95% CI 0.95–0.99), respectively. The SEM between the trials was in each session 0.08 N/mm. The results of this study provide that our robotic technique for quantifying glenohumeral joint stiffness is precise and reproducible. © 2021