Tehran University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
Prognostic Value of Dynamic Renal Scan With 99Mtc-Ec in Patients With Kidney Transplantation: A Prospective Descriptive Study Publisher Pubmed



Arefnia M1 ; Masoumi N2 ; Ghodsirad MA1 ; Moghaddam EJ3 ; Hosseinzadeh E1 ; Hojjati M1
Authors
Show Affiliations
Authors Affiliations
  1. 1. Nuclear Medicine Department, Shohada Tajrish Hospital, School of Medicine, Iran
  2. 2. Department of Urology, Shahid Modarress Hospital, Shahid Beheshti University of Medical Sciences, Iran
  3. 3. Department of Urology, Sina Hospital, Tehran University of Medical Sciences, Tehran Province, Tehran, Iran

Source: Nuclear Medicine Communications Published:2021


Abstract

Introduction Renal transplantation is the gold standard treatment for chronic kidney disease. Renal scintigraphy has been performed widely to evaluate postsurgical complications of transplantation, but there are little data regarding 99mTc-EC scintigraphy in kidney transplantation. Methods and materials This was a prospective descriptive study. All patients who underwent kidney transplantation and passed an uneventful postoperative period entered the study. Demographic characteristics, including age, gender, biochemical parameters before and after the transplantation and 99mTc-EC parameters including time to max, time to max, slope from max to max, upslope time interval and time to 2/3 max as well as episodes of rejection, were recorded. Patients were then followed up for 1 year at 3-, 6-, 9- and 12-month intervals. Results Forty-one patients who underwent renal transplantation entered the study. Mean ± SD age of patients was 40.65 ± 12.84 years (min 17 and max 74 years). In total, 25% (10) of patients experienced one or two episodes of rejection and were hospitalized. Time of max, time of 1/2 max, time from max to 1/2 max, time of 2/3 max, time from max to 2/3 max and upslope time interval had a significant association with transplant rejection using a Cox regression model. With 1-min increase in time of max, the risk of rejection increased by 27% (hazard ratio = 1.27; CI, 1.03 - 1.56) and with 1-min increase in time of 1/2 max, the risk of rejection increased by 28% (hazard ratio = 1.28; CI, 1.14-1.45). Discussion 99mTc-EC renal scintigrahpy was able to predict kidney transplantation rejection in our patients. 99mTc-EC renal scintigrahpy is beneficial to evaluate transplant kidney function to prevent complications and helps close follow-up. © 2021 Lippincott Williams and Wilkins. All rights reserved.