Isfahan University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
Predictive Indicators of the Safety of Swimming Pool Waters Publisher Pubmed



Nikaeen M1 ; Hatamzadeh M1 ; Vahid Dastjerdi M1 ; Hassanzadeh A2
Authors
Show Affiliations
Authors Affiliations
  1. 1. Department of Environmental Health Engineering, Isfahan University of Medical Sciences, Isfahan, Iran
  2. 2. Department of Statistics and Epidemiology, Isfahan University of Medical Sciences, Isfahan, Iran

Source: Water Science and Technology Published:2009


Abstract

Many outbreaks related to swimming pools could have been prevented or reduced if the pool had been well managed and effectively monitored. The aim of this study was to evaluate physicochemical and microbial parameters that can be proposed as an indicator for the safety of swimming pools. A total of 234 water samples, over a 10-month period in 2006-2007, were collected from indoor swimming pools in Isfahan. All water samples were analyzed for physicochemical and microbial parameters including temperature, pH, turbidity, conductivity, free chlorine, heterotrophic plate count (HPC), total (TC) and fecal coliforms (FC), fecal streptococci (FS) Staphylococcus aureus (Sa) and Pseudomonas aeruginosa (Pa). The highest isolation of microbial indicators was for total coliforms (38%) and the lowest for fecal streptococci (3%). The correlation analyses indicated that free chlorine concentration had a significant negative relationship with the heterotrophic bacteria population and total coliforms. Total coliforms presented a significant correlation with the other microbiological indicators. The results clearly showed that the hygienic quality of the swimming pools was dependent on the efficacy of disinfection. Thus, the free chlorine and pH were good operational indices for the quality control of swimming pools and must be maintained in the recommended range to ensure optimal disinfection. The results also showed that TC and HPC were reliable and practical indicators for routine quality surveillance and assessment of the efficiency of the disinfection process and safety of swimming pools. © IWA Publishing 2009.
Other Related Docs
10. Investigation of Hospital Water Systems Contamination to Bacterial Agents of Nosocomial Infections, International Journal of Environmental Health Engineering (2020)
17. Coliforms Removal by an Integrated Activated Sludge-Maturation Pond System, International Journal of Environmental Health Engineering (2013)
19. Detection of Legionella Spp. in Water From Cooling Towers, Journal of Isfahan Medical School (2012)
22. Evaluation of the Microbiological Quality of Wastewater Effluent-Irrigated Maize, Scientific Journal of Kurdistan University of Medical Sciences (2020)
24. Identification of Infectious Bacteria in Dental Units, International Journal of Environmental Health Engineering (2024)
29. Assessment of Drinking Water Quality From Bottled Water Coolers, Iranian Journal of Public Health (2014)
32. Microbial Quality of Water in Dental Unit Waterlines, Journal of Research in Medical Sciences (2009)
34. Detection of E. Coli O157: H7 by Immunological and Real-Time Pcr Methods in the Water Treatment Plant, International Journal of Environmental Health Engineering (2012)