Introduction of a New Parameter for Evaluation of Digital Radiography System Performance Publisher



Choopani M1 ; Chaparian A2
Authors
Show Affiliations
Authors Affiliations
  1. 1. Student Research Committee, Faculty of Paramedicine, Isfahan University of Medical Sciences, Isfahan, Iran
  2. 2. Technology of Radiology Department, Isfahan University of Medical Sciences, Isfahan, Iran

Source: Journal of Medical Signals and Sensors Published:2020


Abstract

Background: The aim of this study was to compare the image quality and radiation doses in various digital radiography systems using contrast-detail radiography (CDRAD) phantom. Methods: The image quality and radiation dose for seven different digital radiography systems were compared using the CDRAD phantom. Incident air kerma (IAK) values were measured for certain exposure settings in all digital radiography systems. The images from the CDRAD phantom were evaluated by three observers. The results were displayed in the form of a contrast-detail (CD) curve. In addition, the inverse image quality figure (IQFinv)-to-IAK ratios were used for quantitative comparison of different digital radiography system performance. Results: Results of this study showed that the CD curves cannot be suitable criterion for determining the performance of digital radiography systems. For this reason, IQFinv-to-radiation dose (IAK) ratios in a fixed radiation condition were used. The highest performance in terms of producing high-quality images and low radiation dose was related to X-ray unit 1 and the lowest performance was for X-ray unit 5. Conclusion: The ratio of IQFinv to IAK for performance evaluation of digital radiography systems is an innovation of this study. A digital radiography system with a higher IQFinv-to-IAK ratio is associated with lower patient dose and better image quality. Therefore, it is recommended to equip the new imaging centers with the systems that have higher IQFinv-to-IAK ratios. © 2020 Isfahan University of Medical Sciences(IUMS). All rights reserved.
Other Related Docs
9. Patient Dose Resulting From Ct Examinations in Yazd, Iran, Iranian Journal of Radiation Research (2006)
11. Monte Carlo Study of Fetal Dosimetry Parameters for 6 Mv Photon Beam, Journal of Medical Signals and Sensors (2013)
13. Conventional and Spiral Ct Dose Indices in Yazd General Hospitals, Iran, Iranian Journal of Radiation Research (2006)
24. Evaluation of Radiographers' and Ct Technologists' Knowledge Regarding Ct Exposure Parameters, Polish Journal of Medical Physics and Engineering (2019)