Isfahan University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
A Simple, Low Cost and Reusable Microfluidic Gradient Strategy and Its Application in Modeling Cancer Invasion Publisher Pubmed



Samandari M1, 2 ; Rafiee L1 ; Alipanah F1 ; Sanatinezhad A3 ; Javanmard SH1
Authors
Show Affiliations
Authors Affiliations
  1. 1. Department of Physiology, Applied Physiology Research Center, Cardiovascular Research Institute, Isfahan University of Medical Sciences, Isfahan, 81746-73461, Iran
  2. 2. Department of Biomedical Engineering, University of Connecticut Health Center, Farmington, 06030, CT, United States
  3. 3. Center for Bioengineering Research and Education, and Department of Mechanical and Manufacturing Engineering, University of Calgary, Calgary, T2N 1N4, AB, Canada

Source: Scientific Reports Published:2021


Abstract

Microfluidic chemical gradient generators enable precise spatiotemporal control of chemotactic signals to study cellular behavior with high resolution and reliability. However, time and cost consuming preparation steps for cell adhesion in microchannels as well as requirement of pumping facilities usually complicate the application of the microfluidic assays. Here, we introduce a simple strategy for preparation of a reusable and stand-alone microfluidic gradient generator to study cellular behavior. Polydimethylsiloxane (PDMS) is directly mounted on the commercial polystyrene-based cell culture surfaces by manipulating the PDMS curing time to optimize bonding strength. The stand-alone strategy not only offers pumpless application of this microfluidic device but also ensures minimal fluidic pressure and consequently a leakage-free system. Elimination of any surface treatment or coating significantly facilitates the preparation of the microfluidic assay and offers a detachable PDMS microchip which can be reused following to a simple cleaning and sterilization step. The chemotactic signal in our microchip is further characterized using numerical and experimental evaluations and it is demonstrated that the device can generate both linear and polynomial signals. Finally, the feasibility of the strategy in deciphering cellular behavior is demonstrated by exploring cancer cell migration and invasion in response to chemical stimuli. The introduced strategy can significantly decrease the complexity of the microfluidic chemotaxis assays and increase their throughput for various cellular and molecular studies. © 2021, The Author(s).