Accuracy Assessment of Ckc High-Density Surface Emg Decomposition in Biceps Femoris Muscle Publisher Pubmed



Marateb HR1, 2 ; Mcgill KC3 ; Holobar A4 ; Lateva ZC3 ; Mansourian M5 ; Merletti R2
Authors
Show Affiliations
Authors Affiliations
  1. 1. Biomedical Engineering Department, Engineering Faculty, University of Isfahan, 81746-73441, Isfahan, HezarJerib st., Iran
  2. 2. Laboratorio di Ingegneria del Sistema Neuromuscolare (LISiN), Dipartimento de Elettronica, Politecnico di Torino, Torino 10129, Italy
  3. 3. Rehabilitation R and D Center, VA Palo Alto Health Care System, Palo Alto, CA 94304, 3801 Miranda Ave, United States
  4. 4. Faculty of Electrical Engineering and Computer Science, University of Maribor, 2000 Maribor, Smetanova ulica 17, Slovenia
  5. 5. Department of Biostatistics and Epidemiology, Health School, Isfahan University of Medical Science, Isfahan, Iran

Source: Journal of Neural Engineering Published:2011


Abstract

The aim of this study was to assess the accuracy of the convolution kernel compensation (CKC) method in decomposing high-density surface EMG (HDsEMG) signals from the pennate biceps femoris long-head muscle. Although the CKC method has already been thoroughly assessed in parallel-fibered muscles, there are several factors that could hinder its performance in pennate muscles. Namely, HDsEMG signals from pennate and parallel-fibered muscles differ considerably in terms of the number of detectable motor units (MUs) and the spatial distribution of the motor-unit action potentials (MUAPs). In this study, monopolar surface EMG signals were recorded from five normal subjects during low-force voluntary isometric contractions using a 92-channel electrode grid with 8 mm inter-electrode distances. Intramuscular EMG (iEMG) signals were recorded concurrently using monopolar needles. The HDsEMG and iEMG signals were independently decomposed into MUAP trains, and the iEMG results were verified using a rigorous a posteriori statistical analysis. HDsEMG decomposition identified from 2 to 30 MUAP trains per contraction. 3 ± 2 of these trains were also reliably detected by iEMG decomposition. The measured CKC decomposition accuracy of these common trains over a selected 10 s interval was 91.5 ± 5.8%. The other trains were not assessed. The significant factors that affected CKC decomposition accuracy were the number of HDsEMG channels that were free of technical artifact and the distinguishability of the MUAPs in the HDsEMG signal (P < 0.05). These results show that the CKC method reliably identifies at least a subset of MUAP trains in HDsEMG signals from low force contractions in pennate muscles. © 2011 IOP Publishing Ltd.