Isfahan University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
Evaluation of Thompson’S Quadricepsplasty Results in Patients With Knee Stiffness Resulted From Femoral Fracture Publisher



Mousavi H1 ; Mir B1 ; Safaei A2
Authors
Show Affiliations
Authors Affiliations
  1. 1. Department of Orthopedics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
  2. 2. Isfahan Medical School Research Center, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran

Source: Journal of Research in Medical Sciences Published:2017


Abstract

Background: Posttraumatic and/or postsurgical knee stiffness is one of the orthopedic complications which is difficult to be treated and can affect individual’s life negatively. The aim of this study is to investigate the results of quadricepsplasty in patients with knee stiffness resulted from femoral fracture. Materials and Methods: This is a cross-sectional study on all patients with femoral fracture which has caused knee flexion limitation referred to Kashani and Al-Zahra Hospitals in Isfahan from January 2010 to March 2013. The type and site of fracture, joint extension, and fracture fixation technique were recorded. Moreover, the range of motion (ROM) before surgery, under general anesthesia, and 3-and 6-month postoperation were measured. Results: Among the patients, 13 had a simple fracture (48%) and 14 had a segmental fracture (51.9%). Considering the fracture site, 11, 10, and 6 patients had femoral (40.74%), supracondylar (37.3%), and femoral supracondylar (22.2%) fractures, respectively. The fracture fixation was performed by the plate, external, and Wagner fixation techniques for 24 (88.9%), 2 (7.4%), and 1 (3.7%) patients, respectively. The mean ROM before operation, under general anesthesia, and 3-and 6-month postoperation were determined to be 33.15° ± 24.73°, 122.60° ± 10.22°,99.63° ± 16.52°, and 100.74° ± 15.67°, respectively. The mean ROM value at various stages was not similar (P < 0.001). The mean changes in the ROM were 79.2° ± 24.6° and 62.1° ± 19.7° in the cases with simple and segmental fractures, respectively. The mean changes in the knee ROM were significantly higher in simple fractures in comparison with the segmental femoral fracture (P = 0.03).Conclusion: We found Thompson’s quadricepsplasty may successfully increase the range of knee flexion in knee fracture and also regardless of quadriceps time. © 2017 Journal of Research in Medical Sciences.
Experts (# of related papers)
Other Related Docs
16. Fixed Versus Mobile Weight-Bearing Prosthesis in Total Knee Arthroplasty, Knee Surgery, Sports Traumatology, Arthroscopy (2012)
20. Risk Factors for Complications in Reconstructing Congenital Femoral Deficiency, Journal of the American Academy of Orthopaedic Surgeons (2024)
21. Using Blumensaat’S Line to Determine the Sagittal Alignment of the Distal Femur, European Journal of Orthopaedic Surgery and Traumatology (2023)
28. Biological Plating of Comminuted Fractures of Femur and Tibia, Journal of Research in Medical Sciences (2007)
33. Floating Knee Injuries: Results of Treatment and Outcomes, Journal of Research in Medical Sciences (2013)
37. Anterior Cruciate Ligament Reconstruction With or Without Bracing, Iranian Journal of Medical Sciences (2006)