Effect of Root Canal Rinsing Protocol on Dentin Bond Strength of Two Resin Cements Using Three Different Method of Test Publisher



Khoroushi M1 ; Sheikhi M2 ; Khaliliangourtani A3 ; Soleimani B4
Authors
Show Affiliations
Authors Affiliations
  1. 1. Dental Materials Research Center and Department of Operative Dentistry, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran
  2. 2. Torabinejad Dental Research Center, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran
  3. 3. Department of Electrical and Computer Engineering, Isfahan University of Technology, Isfahan, Iran
  4. 4. Department of Health and Statistics, Islamic Azad University, Najafabad, Isfahan, Iran

Source: Journal of Clinical and Experimental Dentistry Published:2016


Abstract

Background: Different studies have used different tests to evaluate bond strength of resin cements to root dentin. In this in vitro study, three different tests were used to evaluate the bond strength of two resin cements to root dentin using two root dentin irrigation protocols. Material and Methods: Ninety-six intact single-rooted teeth were selected for this study. Forty-eight teeth, with a root length of 15mm, were randomly divided into two groups and irrigated with normal saline or 2.5% sodium hypochlorite solutions during root canal preparation, respectively. For each 12 specimens from each group, fiber post #1 was bonded using an etch-and-rinse (Duo-Link) and a self-adhesive (BisCem) resin cement, respectively. After incubation, two specimens were prepared for the push-out test from the middle thirds of the roots. In another 24 teeth, after two 1.5-mm sections were prepared from the middle thirds of the prepared roots, sections of the post were bonded in two subgroups with each of the cements mentioned above and the samples were prepared for the pull-out test. For shear test, the crowns of 48 teeth were cut away, the dentin surfaces were prepared, the two irrigation solutions were used, and the resin cements were bonded. Data collected from the three tests were evaluated by ANOVA, post-hoc Tukey and Weibull tests (α=0.05). Results: There were significant differences in the mean bond strength values between the three bond strength tests (P<0.001). Rinsing protocol and cement type resulted in similar variations in the mean bond strength in all tests (P>0.05). Conclusions: Under the limitations of the present study, the method of the test used had an effect on the recorded bond strength between the resin cement and root dentin. Cement type and irrigation protocol resulted in similar variations with all the tests. Push-out and shear tests exhibited more coherent results. © Medicina Oral S.L..
Other Related Docs
30. Effect of Different Chemical Disinfectants on the Flexural Strength of Heat-Polymerized Acrylic Resins, The European journal of prosthodontics and restorative dentistry (2013)