Isfahan University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
The Efficacy of Hemiepiphysiodesis for Idiopathic Knee Coronal Angular Deformity by Reconstruction Plate and Screw: A Pilot Study Publisher



Maleki A1 ; Qoreishi M1 ; Bisadi A1 ; Safdari F1 ; Daei Sorkhabi A2 ; Fotouhi A3 ; Tahririan MA4
Authors
Show Affiliations
Authors Affiliations
  1. 1. Department of Orthopedic Surgery, Akhtar Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran
  2. 2. Student Research Committee, Tabriz University of Medical Sciences, Tabriz, Iran
  3. 3. Department of Orthopedic Surgery, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
  4. 4. Department of Orthopedic Surgery, Faculty of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran

Source: Health Science Reports Published:2023


Abstract

Background: Angular deformities of the lower extremities are among the most common findings in pediatric orthopedics. Alteration of the mechanical axis in the lower extremity affects the cosmetic appearance and may lead to gait disturbances, knee discomfort, patellar maltracking with or without pain, and early joint osteoarthritis. In the current study, we aimed to investigate the efficacy of 3-hole 3.5 mm reconstruction plates in tension-band temporary hemiepiphysiodesis for correcting idiopathic knee coronal angular deformities. Methods: The surgical procedure was performed using an extraperiosteal tension band plate (a 3-hole reconstruction plate) and two 3.5 mm cortical screws to treat idiopathic knee coronal angular deformity in children. The location of the hemiepiphysiodesis was determined based on the type of angular deformity present. Postoperative follow-ups were conducted through x-rays to measure the medial proximal tibial angle and lateral distal femoral angle of the limbs. Statistical analysis was then performed to evaluate the efficacy of the surgical treatment based on the rate of alignment change exhibited. Results: The study included 14 patients (25 limbs) with genu valgum deformity who underwent temporary hemiepiphysiodesis on both the distal femur and proximal tibia, with 16 proximal tibias and 15 distal femurs being corrected. The correction rate for genu valgum was found to be 0.59° per month for both proximal tibial and distal femoral hemiepiphysiodesis. Six patients (12 limbs) were also identified with genu varum deformity, and the correction rates for proximal tibial lateral hemiepiphysiodesis and distal femoral lateral hemiepiphysiodesis were 0.85° and 0.15° per month, respectively. During a mean follow-up duration of 11 ± 5.7 months, only one case of physeal plate closure was observed, and there were no other significant complications. Conclusion: Temporary hemiepiphysiodesis with a 3-hole R-plate and two cortical screws takes advantage of physiological physeal growth to successfully treat idiopathic angular deformities with low complication rates. © 2023 The Authors. Health Science Reports published by Wiley Periodicals LLC.