Isfahan University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
The Elimination of Xylene From Aqueous Solutions Using Single Wall Carbon Nanotube and Magnetic Nanoparticle Hybrid Adsorbent Publisher



Pourzamani H1, 2 ; Parastar S1, 2 ; Hashemi M1, 2, 3
Authors
Show Affiliations
Authors Affiliations
  1. 1. Environment Research Center, Student Research Committee, Research Institute for Primordial Prevention of Non Communicable Disease, Isfahan University of Medical Sciences, Isfahan, Iran
  2. 2. Department of Environmental Health Engineering, School of Health, Isfahan University of Medical Sciences, Isfahan, Iran
  3. 3. Department of Environmental Health Engineering, School of Health, Kerman University of Medical Sciences, Kerman, Iran

Source: Process Safety and Environmental Protection Published:2017


Abstract

Hybrid adsorbent of single wall carbon nanotubes- magnetic nanoparticle (SWCNT-MN) has been used for the elimination of a variety of pollutants. The aim of the present study was to eliminate xylene from aqueous solutions using this hybrid adsorbent. The xylene solution was made in a synthetic manner with 10, 30, 70, and 100 mg/l concentrations. In different pHs (2–11), nanoparticles of magnetic iron were added to the solution in different concentrations namely 500, 1000, 1500, and 2000 g/l and the efficiency of xylene elimination was determined by SWCNT-MN nanoadsorbents after 2–20 min. Xylene was measured using GC/MS device. The data were analyzed by Design Expert software using Taghochi OA method. Also, ISOFIT software was used to investigate the isotherm of xylene adsorption. The optimal conditions of xylene elimination was obtained in primary concentration of 100 mg/l, adsorbent dosage of 2000 mg/l, contact time of 20 min, and pH 8. In the created optimal conditions, 99.2% of xylene was eliminated by SWCNT-MN nanoadsorbents and the adsorption capacity of SWCNT-MN nanoadsorbents for xylene was 50 mg/g. The effect of main factors and important interaction obtained by the software in designing the experiment showed that Prob ˃ F was less than 0.05 for all main factors and the interaction between xylene's primary concentration and SWCNT-MN nanoadsorbents dosage. Among the main factors, the contact time had the highest effect (34%). The investigation of isotherm of xylene adsorption by SWCNT-MN nanoadsorbents indicated that GLF isotherm is the most appropriate adsorption isotherm. © 2017 Institution of Chemical Engineers
Other Related Docs
10. Atenolol Absorption by Multi-Wall Carbon Nanotubes From Aqueous Solutions, Journal of Mazandaran University of Medical Sciences (2017)
11. A Review of the Performance of Carbon Nanotubes in Reducing Environmental Pollution, Journal of Environmental Health and Sustainable Development (2017)
24. Removal of Cr(Vi) From Simulated Electroplating Wastewater by Magnetite Nanoparticles, Environmental Engineering and Management Journal (2010)
31. Nitrate Removal From Aqueous Solutions by Magnetic Nanoparticle, Journal of Environmental Health and Sustainable Development (2017)