A Versatile Biomimic Nanotemplating Fluidic Assay for Multiplex Quantitative Monitoring of Viral Respiratory Infections and Immune Responses in Saliva and Blood Publisher Pubmed



Siavash Moakhar R1 ; Del Real Mata C1 ; Jalali M1 ; Shafique H1 ; Sanati A2 ; De Vries J1 ; Strauss J1 ; Abdelfatah T1 ; Ghasemi F2 ; Mclean M3, 4 ; I Hosseini I1 ; Lu Y1 ; Yedire SG1 ; Mahshid SS5 Show All Authors
Authors
  1. Siavash Moakhar R1
  2. Del Real Mata C1
  3. Jalali M1
  4. Shafique H1
  5. Sanati A2
  6. De Vries J1
  7. Strauss J1
  8. Abdelfatah T1
  9. Ghasemi F2
  10. Mclean M3, 4
  11. I Hosseini I1
  12. Lu Y1
  13. Yedire SG1
  14. Mahshid SS5
  15. Tabatabaiefar MA6
  16. Liang C3, 4
  17. Mahshid S1
Show Affiliations
Authors Affiliations
  1. 1. Department of Bioengineering, McGill University, Montreal, H3A 0E9, QC, Canada
  2. 2. Biosensor Research Center, Isfahan University of Medical Sciences, Isfahan, 81746-73461, Iran
  3. 3. Department of Medicine, McGill University, Montreal, H4A 3J1, QC, Canada
  4. 4. Lady Davis Institute for Medical Research and McGill AIDS Centre, Jewish General Hospital, Montreal, H3T 1E2, QC, Canada
  5. 5. Biological Sciences, Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, M4N 3M5, ON, Canada
  6. 6. Department of Genetics and Molecular Biology, School of Medicine, Isfahan University of Medical Sciences, Isfahan, 81746-73461, Iran

Source: Advanced Science Published:2022


Abstract

The last pandemic exposed critical gaps in monitoring and mitigating the spread of viral respiratory infections at the point-of-need. A cost-effective multiplexed fluidic device (NFluidEX), as a home-test kit analogous to a glucometer, that uses saliva and blood for parallel quantitative detection of viral infection and body's immune response in an automated manner within 11 min is proposed. The technology integrates a versatile biomimetic receptor based on molecularly imprinted polymers in a core–shell structure with nano gold electrodes, a multiplexed fluidic-impedimetric readout, built-in saliva collection/preparation, and smartphone-enabled data acquisition and interpretation. NFluidEX is validated with Influenza A H1N1 and SARS-CoV-2 (original strain and variants of concern), and achieves low detection limit in saliva and blood for the viral proteins and the anti-receptor binding domain (RBD) Immunoglobulin G (IgG) and Immunoglobulin M (IgM), respectively. It is demonstrated that nanoprotrusions of gold electrodes are essential for the fine templating of antibodies and spike proteins during molecular imprinting, and differentiation of IgG and IgM in whole blood. In the clinical setting, NFluidEX achieves 100% sensitivity and 100% specificity by testing 44 COVID-positive and 25 COVID-negative saliva and blood samples on par with the real-time quantitative polymerase chain reaction (p < 0.001, 95% confidence) and the enzyme-linked immunosorbent assay. © 2022 The Authors. Advanced Science published by Wiley-VCH GmbH.