Impact of Harmonization on the Reproducibility of Mri Radiomic Features When Using Different Scanners, Acquisition Parameters, and Image Pre-Processing Techniques: A Phantom Study Publisher



Hajianfar G1 ; Hosseini SA2, 3 ; Bagherieh S4 ; Oveisi M5 ; Shiri I1, 6 ; Zaidi H1, 7, 8, 9
Authors
Show Affiliations
Authors Affiliations
  1. 1. Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva, CH-1211, Switzerland
  2. 2. Translational Neuroimaging Laboratory, McGill University Research Centre for Studies in Aging, Douglas Hospital, McGill University, Montreal, QC, Canada
  3. 3. Department of Neurology and Neurosurgery, Faculty of Medicine, McGill University, Montreal, QC, Canada
  4. 4. School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
  5. 5. Department of Computer Science, University of British Columbia, Vancouver, BC, Canada
  6. 6. Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
  7. 7. Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen, Netherlands
  8. 8. Department of Nuclear Medicine, University of Southern Denmark, Odense, Denmark
  9. 9. University Research and Innovation Center, Obuda University, Budapest, Hungary

Source: Medical and Biological Engineering and Computing Published:2024


Abstract

This study investigated the impact of ComBat harmonization on the reproducibility of radiomic features extracted from magnetic resonance images (MRI) acquired on different scanners, using various data acquisition parameters and multiple image pre-processing techniques using a dedicated MRI phantom. Four scanners were used to acquire an MRI of a nonanatomic phantom as part of the TCIA RIDER database. In fast spin-echo inversion recovery (IR) sequences, several inversion durations were employed, including 50, 100, 250, 500, 750, 1000, 1500, 2000, 2500, and 3000 ms. In addition, a 3D fast spoiled gradient recalled echo (FSPGR) sequence was used to investigate several flip angles (FA): 2, 5, 10, 15, 20, 25, and 30 degrees. Nineteen phantom compartments were manually segmented. Different approaches were used to pre-process each image: Bin discretization, Wavelet filter, Laplacian of Gaussian, logarithm, square, square root, and gradient. Overall, 92 first-, second-, and higher-order statistical radiomic features were extracted. ComBat harmonization was also applied to the extracted radiomic features. Finally, the Intraclass Correlation Coefficient (ICC) and Kruskal-Wallis’s (KW) tests were implemented to assess the robustness of radiomic features. The number of non-significant features in the KW test ranged between 0–5 and 29–74 for various scanners, 31–91 and 37–92 for three times tests, 0–33 to 34–90 for FAs, and 3–68 to 65–89 for IRs before and after ComBat harmonization, with different image pre-processing techniques, respectively. The number of features with ICC over 90% ranged between 0–8 and 6–60 for various scanners, 11–75 and 17–80 for three times tests, 3–83 to 9–84 for FAs, and 3–49 to 3–63 for IRs before and after ComBat harmonization, with different image pre-processing techniques, respectively. The use of various scanners, IRs, and FAs has a great impact on radiomic features. However, the majority of scanner-robust features is also robust to IR and FA. Among the effective parameters in MR images, several tests in one scanner have a negligible impact on radiomic features. Different scanners and acquisition parameters using various image pre-processing might affect radiomic features to a large extent. ComBat harmonization might significantly impact the reproducibility of MRI radiomic features. Graphical Abstract: (Figure presented.) © The Author(s) 2024.