Development of a Preclinical Pet System Based on Pixelated Lyso Crystals and Sipm Arrays Publisher



Zeraatkar N1 ; Sajedi S2 ; Kaviani S2 ; Taheri M2 ; Khanmohammadi H2 ; Sarkar S3 ; Ay MR2
Authors
Show Affiliations
Authors Affiliations
  1. 1. Department of Radiology, University of Massachusetts Medical School, Worcester, MA, United States
  2. 2. Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran
  3. 3. Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran

Source: 2017 IEEE Nuclear Science Symposium and Medical Imaging Conference# NSS/MIC 2017 - Conference Proceedings Published:2018


Abstract

PET imaging is playing an important role in the field of molecular imaging regarding its high sensitivity in detection of radiotracers. Hence, development of dedicated preclinical PET scanners with better performance parameters utilizing state-ofthe-art technology has an ongoing trend. We recently developed a prototype preclinical PET scanner based on pixelated lutetiumyttrium oxyorthosilicate (LYSO) crystals and Silicon Photomultiplier (SiPM) arrays. In this paper, we report on the system design properties together with calibration/correction algorithms, image reconstruction, and preliminary evaluation of performance parameters and animal imaging. The detection subsystem consists of 10 blocks forming a full-ring bore. Each block is composed of attachment of a24 \times 24 LYSO crystal array to a12 \times 12 SiPM array. After pre-processing and time-stamping in each block, a mainboard is responsible for acquiring the data from all the blocks, coincidence detection, position extraction, and transferring them to a computer where other processing steps are performed. The initial assessments showed that the spatial resolution of the system at the center of field-of-view is about 1.8 mm while the sensitivity is around 1.4%. Also, reconstructed images of a rat scan after administration of 7.4 MBq 18F-sodium fluoride (NaF) revealed acceptable performance of the scanner in imaging of animal models. Time resolution and average energy resolution of the system after corresponding corrections were measured as 1.85 ns and 12.5%, respectively. © 2017 IEEE.