Tehran University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
8-Hydroxy-2′-Deoxyguanosine (8-Ohdg) As a Biomarker of Oxidative Dna Damage Induced by Occupational Exposure to Nanomaterials: A Systematic Review Publisher Pubmed



Omari Shekaftik S1 ; Nasirzadeh N2
Authors
Show Affiliations
Authors Affiliations
  1. 1. Department of Occupational Health Engineering, Faculty of public health, Iran University of Medical Sciences, Tehran, Iran
  2. 2. Department of Occupational Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran

Source: Nanotoxicology Published:2021


Abstract

In nuclear and mitochondrial DNA, 8-hydroxy-2′-deoxyguanosine (8-OHdG) is one of the predominant forms of reactive oxygen species (ROSs) lesions, which commonly used as a biomarker for oxidative stress. Studies showed that the different nanomaterials can induce toxicity by ROSs in human body. So, this study is going to review the studies about oxidative DNA damage caused by occupational exposure to nanomaterials, using 8-OHdG biomarker. Systematic review was managed based on Cochrane systematic review guideline. Literature search was conducted in scientific databases with the main terms of “biomarkers,” “biological markers,” combined with “occupational exposure” and “nanomaterials.” All papers in the field of occupational exposure to nanomaterials until 2020 December were included. To evaluate the quality and bias of studies, GRADE method (Grading of Recommendations, Assessment, Development, and Evaluation) was used. Two hundred twenty-six studies were primarily achieved. By considering the inclusion criteria, overall 8 articles were selected. The majority of the studies were classified as the moderate quality studies (six studies). Also, the study-level bias was critical. This review shows that there is a significant relationship between job title and amount of produced nanomaterials and the existence of 8-OHdG. Also, the levels of 8-OHdG can be measured in urine, blood, and inhalation samples by instrumental procedures. Oxidative damages are an important threat for workers exposed to nanomaterial. Blood and EBC 8-OHdG level can be introduced as a biomarker for metal nanomaterials, but urinary 8-OHdG needs to be taken with caution. So, it is recommended that evaluation not be solely based on one biomarker. © 2021 Informa UK Limited, trading as Taylor & Francis Group.