Tehran University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
Pipeline Embolization Device and Flow Re-Direction Endoluminal Device for Intracranial Aneurysms: A Comparative Systematic Review and Meta-Analysis Study Publisher Pubmed



Rashidi F1 ; Habibi MA2 ; Reyhani M3 ; Fallahi MS1 ; Arshadi MR1 ; Sabahi M4 ; Vakharia K5 ; Rahimi SY6
Authors
Show Affiliations
Authors Affiliations
  1. 1. School of Medicine, Tehran University of Medical Sciences, Tehran, Iran
  2. 2. Department of Neurosurgery, Tehran University of Medical Sciences, Tehran, Iran
  3. 3. School of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
  4. 4. Department of Neurological Surgery, Pauline Braathen Neurological Center, Cleveland Clinic Florida, Weston, FL, United States
  5. 5. Department of Neurosurgery and Brain Repair, University of South Florida, Morsani College of Medicine, Tampa, FL, United States
  6. 6. Department of Neurosurgery, Medical College of Georgia, Augusta University, Augusta, GA, United States

Source: World Neurosurgery Published:2024


Abstract

Background: When it comes to intracranial aneurysms, the quest for more effective treatments is ongoing. Flow diversion represents a growing advancement in this field. This review seeks to compare 2 variants of the endovascular flow diversion method: the Flow Re-Direction Endoluminal Device (FRED) and the Pipeline Embolization Device (PED). Methods: A systematic review was conducted according to the PRISMA guideline using PubMed, Scopus, Web of Science, and Embase, using appropriate terms to compare PED and FRED in double-arm studies from conception until October 8th, 2023. Results: The meta-analysis encompassed 1769 patients, with a predominance of females (75.5%), among whom 973 patients underwent FRED procedures, while 651 received PED interventions. At 6 months, complete occlusion rates were 0.62 for FRED and 0.68 for PED (P = 0.68). At 1 year and the last follow-up, no significant differences were observed between FRED and PED, respectively. Adequate occlusion rates were similar between FRED and PED (0.82 vs. 0.79, P = 0.68). FRED showed a statistically significant higher rate of good mRS scores at follow-up (1.00 vs. 0.97, P = 0.03). Hemorrhage and re-treatment rates were higher in PED (P < 0.01) without considering the rupture status of the aneurysms due to the lack of data. Conclusions: This meta-analysis suggests comparable efficacy but different safety profiles between FRED and PED in treating intracranial aneurysms. FRED demonstrated a higher rate of good modified Rankin scores, while PED showed increased hemorrhage and re-treatment rates. Understanding these differences is crucial for informed decision-making in clinical practice. © 2024 Elsevier Inc.