Isfahan University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
Evaluation of Bio-Aerosols Concentration in the Different Wards of Three Educational Hospitals in Iran Publisher



Nourmoradi H1 ; Amin MM2, 3 ; Hatamzadeh M2, 3 ; Nikaeen M2, 3
Authors
Show Affiliations
Authors Affiliations
  1. 1. Department of Environmental Health Engineering, School of Health, Ilam University of Medical Sciences, Ilam, Iran
  2. 2. Environment Research Center, Isfahan University of Medical Sciences (IUMS), Isfahan, Iran
  3. 3. Department of Environmental Health Engineering, School of Health, IUMS, Isfahan, Iran

Source: International Journal of Environmental Health Engineering Published:2012


Abstract

Aims: The aim of this study was to evaluate the bioaerosols level in the various parts of three educational hospitals of Isfahan, Iran. Materials and Methods: The collection of bioaerosols (including bacterial and fungal microorganisms) was carried out with one-stage Anderson sampler. The sampling was carried out at the height of 1.5 m from the floor of various hospitals wards (infectious, surgery, urology wards, and operating room). The volume of each sample was determined based on pre-Tests carried and was about 50 L. After sampling, the samples were incubated and analyzed. The effect of various environmental conditions including humidity, temperature, and outdoor bioaerosol levels was also investigated. Results: The lowest numbers of fungal and bacterial concentration were obtained in operating rooms of the hospitals and the highest concentration was observed in infectious disease wards of hospital 1 and 2 and surgery ward of hospital 3. The bacterial concentration was observed to be higher in hospital wards than outdoor, except hospitals operating rooms. Conclusion: The findings showed that the bioaerosols level in the hospitals was relatively high. The higher levels of indoor bacteria than outdoor might be associated with the presence of patients, their activity, unsuitable ventilation, and disinfection. Therefore, environmental monitoring and control measures are required to improve hospital environmental quality especially in the wards with immune deficiency patients. © 2012 Medknow. All Rights Reserved.
Other Related Docs
12. Investigation of Hospital Water Systems Contamination to Bacterial Agents of Nosocomial Infections, International Journal of Environmental Health Engineering (2020)
13. Fungal Presence and Health Implications in Hospital Water Systems, International Journal of Environmental Health Research (2024)
19. Health-Care Waste Management Status in Iran (Case Study of Gachsaran County, 2012-2013), International Journal of Environmental Health Engineering (2016)