Isfahan University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
A Comparative Sem Study Between Hand Instrument and Er:Yag Laser Scaling and Root Planing Publisher Pubmed



Moghare Abed A1 ; Tawakkoli M1 ; Dehchenari MA1 ; Gutknecht N2 ; Mir M2
Authors
Show Affiliations
Authors Affiliations
  1. 1. Dental School, Isfahan Medical University, Isfahan, Tehran, Iran
  2. 2. Aachen Dental Laser Research Centre, RWTH Hospital, Aachen, Germany

Source: Lasers in Medical Science Published:2007


Abstract

Scaling and root planing are one of the most commonly used procedures for the treatment of periodontal diseases. Removal of calculus using conventional hand instruments is incomplete and rather time-consuming. In search for more efficient and less difficult instrumentation, investigators have proposed lasers as alternatives or adjuncts for scaling and root planing. The aim of the present study was to compare the effectiveness of subgingival scaling and root planing with erbium: yttrium, aluminium, garnet (Er:YAG) laser and hand instrumentation in vitro. The mesial and distal surfaces of 15 periodontal loosed extracted teeth were treated randomly either by hand instrumentation or by Er:YAG laser irradiation. After choosing the very long pulse mode (pulse duration of about 700 μs), the output energy of 160 mJ with 920-μm beam diameter (RO7 Perio tip, Fidelis, Fotona, Slovenia) and frequency of 12 Hz were selected, both according to the best results of past studies. In addition, air water spray was used during the procedures. The morphology of the root surface was evaluated by three observers with a scanning electron microscopy in magnifications of 50x and 400x. The result of this setting showed that the rate of remained roughness on treated root surfaces in two groups of hand instruments and Er:YAG laser had a meaningful difference: The surface roughness in Er:YAG laser group was more than in hand instruments group. The present study could demonstrate the in vitro capability of the Er:YAG laser for scaling and root planing in periodontitis, although the effectiveness of this setting did not reach that achieved by hand instrumentation. It could be concluded that lower frequency and long pulse duration maybe more suitable for the micro-morphology of root surface after treatment. This theory is going to be tested with the same laser instrument in the next study. © 2006 Springer-Verlag London Limited.
Other Related Docs
26. Ft-Raman Spectroscopic Studies of Nd/Yag Laser-Irradiated Human Dental Enamel, Iranian Journal of Chemistry and Chemical Engineering (2002)