Tehran University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
Clinical Outcomes of a New Type of Continuous Intrastromal Corneal Ring for Treatment of Keratoconus Publisher Pubmed



Jabbarvand M1 ; Ahmadzadeh H2 ; Khodaparast M1 ; Jamali A3 ; Aghamirsalim M4
Authors
Show Affiliations
Authors Affiliations
  1. 1. Eye Research Center, Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, 1336616351, Iran
  2. 2. School of Medicine, Tehran University of Medical Sciences, Tehran, Iran
  3. 3. Rehabilitation Research Center, Department of Optometry, School of Rehabilitation Sciences, Iran University of Medical Sciences, Tehran, Iran
  4. 4. Translational Ophthalmology Research Center, Tehran University of Medical Sciences, Tehran, Iran

Source: Cornea Published:2022


Abstract

Purpose:The purpose of this study was to evaluate the efficacy and safety of implantation of a new continuous corneal ring in keratoconic corneas of an Iranian population.Methods:This study was conducted on 95 contact lens-intolerant keratoconic eyes with clear central corneas. A continuous corneal ring, annular intrastromal corneal inlay (AICI), was inserted using femtosecond laser in all cases. Patients were followed up for 1, 3, and 12 months postsurgery. Visual and subjective refractive outcomes were evaluated in each examination. Besides, keratometry and aberrometric values were recorded before and 12 months after surgery. Finally, vector analysis of refractive astigmatism was performed using the Alpins method.Results:The uncorrected and corrected distance visual acuities improved significantly 12 months after surgery from 0.91 ± 0.39 to 0.38 ± 0.22 (P < 0 0.001) and 0.33 ± 0.21 to 0.13 ± 0.11 logMAR (P < 0.001), respectively. Moreover, spherical and cylindrical refractive components reduced from -2.52 ± 2.62 to -0.76 ± 1.78 D (P < 0.001) and -4.14 ± 1.64 to -1.91 ± 1.18 D (P < 0.001), respectively. The mean anterior keratometry had a significant reduction 12 months after AICI insertion (P< 0.001). Primary coma and spherical aberration values showed a significant increase (both, P < 0.05). Our results showed 100% safety (safety index: 1.8) and 45% efficacy (efficacy index: 1).Conclusions:AICI implantation seemed to be a safe and effective procedure for improving visual acuity and refractive outcomes in subjects with keratoconus. © 2022 Lippincott Williams and Wilkins. All rights reserved.
Other Related Docs
12. Long-Term Results of Myoring Implantation in Patients With Keratoconus, Clinical and Experimental Optometry (2021)
22. Visual Outcomes After Femtosecond-Assisted Intracorneal Myoring Implantation: 18 Months of Follow-Up, Graefe's Archive for Clinical and Experimental Ophthalmology (2016)
23. Microbial Keratitis Following Intracorneal Ring Implantation, Clinical and Experimental Optometry (2019)
28. Customized Stromal Lenticule Implantation for Keratoconus, Journal of Refractive Surgery (2020)