Linear Momenta Transferred to the Dental Implant-Bone and Natural Tooth—Pdl-Bone Constructs Under Impact Loading: A Comparative In-Vitro and In-Silico Study Publisher



Karimi Dastgerdi A1 ; Rouhi G1 ; Dehghan MM2, 3 ; Farzadmohajeri S3 ; Barikani HR4
Authors
Show Affiliations
Authors Affiliations
  1. 1. Faculty of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran
  2. 2. Department of Surgery and Radiology, Faculty of Veterinary Medicine, University of Tehran, Tehran, Iran
  3. 3. Institute of Biomedical Research, University of Tehran, Tehran, Iran
  4. 4. Dental Implant Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran

Source: Frontiers in Bioengineering and Biotechnology Published:2020


Abstract

During dental trauma, periodontal ligament (PDL) contributes to the stability of the tooth-PDL-bone structure. When a dental implant is inserted into the bone, the dental implant-bone construct will be more prone to mechanical damage, caused by impact loading, than the tooth-PDL-bone construct. In spite of the prevalence of such traumas, the behavioral differences between these two constructs have not been well-understood yet. The main goal of this study was to compare the momentum transferred to the tooth-PDL-bone and dental implant-bone constructs under impact loading. First, mechanical impact tests were performed on six canine mandibles of intact (N = 3) and implanted (N = 3) specimens using a custom-made drop tower apparatus, from release heights of 1, 2, and 3 cm. Next, computed tomography-based finite element models were developed for both constructs, and the transferred momenta were calculated. The experimental results indicated that, for the release heights of 1, 2, and 3 cm, the linear momenta transferred to the dental implant-bone construct were 33.1, 31.0, and 27.5% greater than those of the tooth-PDL-bone construct, respectively. Moreover, results of finite element simulations were in agreement with those of the experimental tests (error <7.5%). This work tried to elucidate the effects of impact loading on the dental implant-bone and tooth-PDL-bone constructs using both in-vitro tests and validated in-silico simulations. The findings can be employed to modify design of the current generation of dental implants, based on the lessons one can take from the biomechanical behavior of a natural tooth structure. © Copyright © 2020 Karimi Dastgerdi, Rouhi, Dehghan, Farzad-Mohajeri and Barikani.