Tehran University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
Effect of Implant Angulation on the Rotational Displacement of a 3-Unit Bridge After Digital Impression Publisher



Arshad M1, 2 ; Asgari A3 ; Kharazifard MJ4 ; Ameri N1, 2
Authors
Show Affiliations
Authors Affiliations
  1. 1. Dental Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, 14399-55991, Iran
  2. 2. Department of Prosthodontics, School of Dentistry, International Campus, Tehran University of Medical Sciences, Tehran, 14399-55991, Iran
  3. 3. Tehran, Iran
  4. 4. Department of Epidemiology and Biostatistics, Faculty of Public Health, Dental School, Tehran University of Medical Sciences, Tehran, 14399-55991, Iran

Source: International Journal of Dentistry Published:2022


Abstract

Objectives. This study aimed to assess the effect of implant angulation on the rotational displacement of a 3-unit bridge following a digital impression. Materials and Methods. This in vitro experimental study evaluated 3 master models of the maxilla with Kennedy's class III partial edentulism and bilateral three-unit implant-supported fixed partial dentures. Two implants were placed with 0° (first model), 15° (second model), and 30° (third model) interimplant angles. The implants were placed bilaterally at the sites of first premolars and first molars from the posterior towards the anterior region and coded A (posterior) and B (anterior) in the left, and C (posterior) and D (anterior) in the right side. Next, their position was recorded using a coordinate measuring machine to serve as a reference. The models were then scanned by both 3Shape and Sirona digital scanners (12 times by each scanner). The obtained data were compared with the reference data three-dimensionally using GOM Inspect software to determine the rotational displacement of the implants. Data were analyzed by repeated-measures ANOVA, one-way ANOVA, paired sample t-test, and independent sample t-test (P < 0.05). Results. Since repeated-measures ANOVA showed that the interaction effect was significant (P = 0.010), the data were analyzed by subgroup analysis. The 3Shape scanner showed significantly higher accuracy for C-D region in model 2 (P = 0.001), and A-B region in model 1 (P ≤ 0.01). In the use of the 3Shape scanner, model 3 showed a lower error rate in the A-B region, compared with models 1 and 2. Model 1 showed higher error rate than models 2 and 3 in the C-D region (P ≤ 0.01). In the use of the Sirona scanner, model 1 showed a higher error rate than models 2 (P = 0.031) and 3 (P = 0.004) in the C-D region. Conclusion. In digital impressions of angulated implants in 3-unit bridges by using 3Shape and Sirona scanners, the rotational error decreases as the interimplant angle increases. © 2022 Mahnaz Arshad et al.
Other Related Docs
6. Do Type and Shape of Scan Bodies Affect Accuracy and Time of Digital Implant Impressions?, European Journal of Prosthodontics and Restorative Dentistry (2020)
14. Effect of Arch Size and Implant Angulations on the Accuracy of Implant Impressions, European Journal of Prosthodontics and Restorative Dentistry (2021)
16. A Comparison of Implant Impression Precision: Different Materials and Techniques, Journal of Clinical and Experimental Dentistry (2018)