Focal Cortical Dysplasia Detection by Artificial Intelligence Using Mri: A Systematic Review and Meta-Analysis Publisher Pubmed



Dashtkoohi M1, 2 ; Ghadimi DJ3 ; Moodi F1, 4 ; Behrang N5 ; Khormali E6 ; Salari HM1 ; Cohen NT7 ; Gholipour T8 ; Saligheh Rad H1, 9
Authors
Show Affiliations
Authors Affiliations
  1. 1. Quantitative MR Imaging and Spectroscopy Group (QMISG), Tehran University of Medical Sciences, Tehran, Iran
  2. 2. Interdisciplinary Neuroscience Research Program, Tehran University of Medical Sciences, Tehran, Iran
  3. 3. School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
  4. 4. School of Medicine, Iran University of Medical Sciences, Tehran, Iran
  5. 5. Computer Science Department, Sharif University of Technology, Tehran, Iran
  6. 6. Student Research Committee, School of Medicine, Mazandaran University of Medical Sciences, Sari, Iran
  7. 7. Center for Neuroscience Research, Children's National Hospital, The George Washington University School of Medicine, Washington, DC, United States
  8. 8. Department of Neurosciences, University of California San Diego, La Jolla, CA, United States
  9. 9. Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran

Source: Epilepsy and Behavior Published:2025


Abstract

Purpose: Focal cortical dysplasia (FCD) is a common cause of pharmacoresistant epilepsy. However, it can be challenging to detect FCD using MRI alone. This study aimed to review and analyze studies that used machine learning and artificial neural networks (ANN) methods as an additional tool to enhance MRI findings in FCD patients. Methods: A systematic search was conducted in four databases (Embase, PubMed, Scopus, and Web of Science). The quality of the studies was assessed using QUADAS-AI, and a bivariate random-effects model was used for analysis. The main outcome analyzed was the sensitivity and specificity of patient-wise outcomes. Heterogeneity among studies was assessed using I2. Results: A total of 41 studies met the inclusion criteria, including 24 ANN-based studies and 17 machine learning studies. Meta-analysis of internal validation datasets showed a pooled sensitivity of 0.81 and specificity of 0.92 for AI-based models in detecting FCD lesions. Meta-analysis of external validation datasets yielded a pooled sensitivity of 0.73 and specificity of 0.66. There was moderate heterogeneity among studies in the external validation dataset, but no significant publication bias was found. Conclusion: Although there is an increasing number of machine learning and ANN-based models for FCD detection, their clinical applicability remains limited. Further refinement and optimization, along with longitudinal studies, are needed to ensure their integration into clinical practice. Addressing the identified limitations and intensifying research efforts will improve their relevance and reliability in real medical scenarios. © 2025