Isfahan University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
Three Dimensional Film Dosimetry of Photon Beam in Small Field Sizes and Beyond the Heterogeneous Regions Using a Gafchromic Films Array Publisher



Arabbafrani Z1, 2 ; Mahani L3, 4 ; Khoshbinkhoshnazar A1, 2 ; Kermani MZ5
Authors
Show Affiliations
Authors Affiliations
  1. 1. Metabolic Disorders Research Center, Golestan University of Medical Sciences, Gorgan, Iran
  2. 2. Department of Biochemistry and Biophysics, Faculty of Medicine, Golestan University of Medical Sciences, Gorgan, Iran
  3. 3. Department of Medical Physics, Faculty of Medicine, Urmia University of Medical Sciences, Urmia, Iran
  4. 4. Department of Radiation Oncology, Seyed Al-Shohada Hospital, Isfahan University of Medical Sciences, Isfahan, Iran
  5. 5. Department of Radiation Oncology, Shafa Hospital, Kerman, Iran

Source: Radiation Physics and Chemistry Published:2020


Abstract

Introduction: Inaccurate dose prediction by treatment planning system (TPS) beyond the heterogeneous regions has been a great challenge in radiotherapy, particularly when small field sizes are used. Better understanding of this inaccuracy that depends on dosimetry methods is very crucial. Recently, the film stack dosimeter has been purposed for 3D comprehensive dosimetry. This study proposes an approach to investigate the accuracy of TPS for predicting dose distribution in small field sizes in the presence of nasopharynx heterogeneities by 3D stack film. Material & methods: The dose distribution and dose profile of rectangular heterogeneous nasopharynx (RHN) phantom with two air cavities and bone equivalent were measured with a 3D stack film dosimeter containing 9 GAFchromic-EBT2 films positioned beyond the heterogeneity regions. The film was validated using MCNPX-Monte Carlo (MC) simulation. The evaluation of TPS inaccuracy in small field sizes (3 × 3, 4 × 4, 5 × 5 cm2) was determined by comparing reconstructed 3D dose distribution of stack film dosimeter with TPS based on full scatter convolution (FSC) using in-house Matlab code. Results: The film measurements had a good agreement with the MC calculation for small fields in RHN phantom. The results showed a large discrepancy between stack film measurements and TPS calculations in the volumes enclosed high isodoses, so that the biggest difference occurred in 3 × 3 cm2 field size (relative mean difference = 1.72 ± 0.24, 1.5 ± 0.16 and P-value = 0.002, 0.001 for V95 and V90 respectively) and it decreased in 5 × 5 cm2 field size (relative mean difference = 0.46 ± 0.05, 0.35 ± 0.04 and P-value = 0.001, 0.002 for V95 and V90 respectively). Conclusion: The results suggested that 3D stack film dosimetry can be successfully used as a reliable dosimeter for QA procedure of heterogeneous region in small field sizes. Comparison of the measured and calculated dose volumes demonstrated that the TPS based FSC algorithm has a notable inaccuracy in estimation of dose distribution beyond the nasopharynx heterogeneities. Therefore: it seems heterogeneity corrections should be considered for nasopharynx treatment. © 2019 Elsevier Ltd
Experts (# of related papers)
Other Related Docs
23. Optimization of Ct Slice Thickness in 3D-Crt and Imrt Planning of Low Grade Glioma, International Journal of Radiation Research (2021)
24. Sensitivity Analysis of a 6 Mev Photon Beam Monte Carlo Model, Journal of Medical Signals and Sensors (2023)
28. Monte Carlo Study of Fetal Dosimetry Parameters for 6 Mv Photon Beam, Journal of Medical Signals and Sensors (2013)
50. Dose Response Evaluation of a Low Density Anoxic Polymer Gel Dosimeter Using Mri, International Journal of Radiation Research (2015)