Isfahan University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
Comparison of Pet/Ct and Ct-Based Tumor Delineation and Its Effects on the Radiation Treatment Planning for Non-Small Cell Lung Cancer



Yaraghi Y1 ; Jabbari I1 ; Akhavan A2 ; Ghaffarian P3 ; Monadi S2 ; Saeb M4
Authors
Show Affiliations
Authors Affiliations
  1. 1. Department of Nuclear Engineering, Faculty of Advanced Sciences and Technologies, University of Isfahan, Isfahan, 8174673441, Iran
  2. 2. Department of Radiation Oncology, Seyed Al-Shohada Hospital, Isfahan University of Medical Sciences, Isfahan, Iran
  3. 3. PET/CT and Cyclotron Center, Masih Daneshvari Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran
  4. 4. Department of Medical Physics, Isfahan University of Medical Sciences, Isfahan, Iran

Source: Iranian Journal of Nuclear Medicine Published:2018

Abstract

Introduction: Tumor volume delineation is the most important step in the radiation treatment planning. In this study the impact of PET/CT data on the tumor delineation precision of non-small cell lung cancer (NSCLC) was investigated. Methods: PET/CT images of 20 patients with primary NSCLC were obtained and imported to the treatment planning system for image fusion, contouring and radiation treatment planning. For each patient two separate gross tumor volumes were delineated based on CT and PET/CT images as GTVCT and GTVPET/CT, respectively. In addition, three different indices including conformity index (CI), geographic miss index (GMI) and geographic include index (GII) were calculated to quantify the match and mismatches degree between derived volumes. Then, for each patient an appropriate 3D conformal treatment plan was made based on the PTVCT and then these plans were applied on the PTVPET/CT. Afterwards, the dose coverage of PTVPET/CT was estimated through several dosimetric parameters. Results: The GTVPET/CT was larger than GTVCT for majority of cases. The 25% exceeded volumetric alterations were observed in 8 of all cases (40%). Mean values of CI, GMI and GII were 0.43, 0.42 and 0.34, respectively. Also, dosimetric parameters indicated inadequate dose coverage of PTVPET/CT in CT-based RT plans for most of the patients. Conclusion: Incorporating PET data into tumor delineation process had a great potential to improve the quality of radiation treatment planning for NSCLC. © 2018 Tehran University of Medical Sciences. All rights reserved.
Experts (# of related papers)
Other Related Docs
16. Secondary Cancer Risk After Radiotherapy of Seminoma Stage One, Iranian Journal of Medical Physics (2022)
25. Conventional and Spiral Ct Dose Indices in Yazd General Hospitals, Iran, Iranian Journal of Radiation Research (2006)
36. Dynamic Mlc Tracking Using 4D Lung Tumor Motion Modelling and Epid Feedback, Journal of Biomedical Physics and Engineering (2019)