Evaluation of Microgap Size and Microbial Leakage in the Connection Area of 4 Abutments With Straumann (Iti) Implant Publisher Pubmed



Rismanchian M1 ; Hatami M2 ; Badrian H3 ; Khalighinejad N3 ; Goroohi H3
Authors
Show Affiliations
Authors Affiliations
  1. 1. Dental Implant Research Center, Department of Prosthodontics, Isfahan University of Medical Sciences, Isfahan, Iran
  2. 2. Department of Prosthodontics, Dental School, Yazd Shahid Sadooghi University of Medical Sciences, Yazd, Iran
  3. 3. Dental Implant Research Center, Dental School, Isfahan University of Medical Sciences, Isfahan, Iran

Source: Journal of Oral Implantology Published:2012


Abstract

A microgap between implant and abutment can lead to mechanical and biological problems such as abutment screw fracture and peri-implantitis. The aim of this study was to evaluate microgap size and microbial leakage in the connection area of 4 different abutments to ITI implants. In this experimental study, 36 abutments in 4 groups (including Cast On, Castable, Solid, and Synocta abutments) connected to Straumann fixtures (with their inner part inoculated with bacterial suspension) and microbial leakage were assessed at different times. The size of the microgap in 4 randomized locations was then measured by scanning electron microscope. The data were analyzed by SPSS software and by 1-way variance statistical test, Kruskal-Wallis, and their supplementary tests (Mann-Whitney HSD and Tukey's; α= .05) at the next step. The effect of using different types of abutments was significant on the mean microgap size (P < .001) and on the mean number of leaked colonies (CFU/mL) through the connection area of the implant and abutment within the first 5 hours of the experiment (P = .012); however, it did not significantly influence microleakage at 24 hours, 48 hours, and 14 days (P = .145). Using Synocta abutments compared with Solid abutments will not provide us with more accommodation, and vice versa. Using Solid and Synocta abutments can significantly decrease the microgap size; however, Cast On abutments do not show a significant difference in terms of microgap compared with Castable abutments. Microleakage in the connection area is comparable for these 4 abutments.
Experts (# of related papers)
Other Related Docs
18. Bone Loss-Related Factors in Tissue and Bone Level Dental Implants: A Systematic Review of Clinical Trials, Journal of the Korean Association of Oral and Maxillofacial Surgeons (2021)