Isfahan University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
Stress Analysis of Different Prosthesis Materials in Implant-Supported Fixed Dental Prosthesis Using 3D Finite Element Method Publisher



Iranmanesh P1 ; Abedian A2 ; Nasri N1 ; Ghasemi E1 ; Khazaei S1, 3
Authors
Show Affiliations
Authors Affiliations
  1. 1. Department of Prosthodontics, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran
  2. 2. Department of Mechanical Engineering, Daneshpajoohan Higher Education Institute, Isfahan, Iran
  3. 3. Department of Research, School of Dentistry, Kermanshah University of Medical Sciences, Kermanshah, Iran

Source: Dental Hypotheses Published:2014


Abstract

Introduction: In the present study, the finite element method (FEM) was used to investigate the effects of prosthesis material types on stress distribution of the bone surrounding implants and to evaluate stress distribution in three-unit implant-supported fixed dental prosthesis (FDP). Materials and Methods: A three-dimensional (3D) finite element FDP model of the maxillary second premolar to the second molar was designed. Three load conditions were statically applied on the functional cusps in horizontal (57.0 N), vertical (200.0 N), and oblique (400.0 N, θ = 120°) directions. Four standard framework materials were evaluated: Polymethyl methacrylate (PMMA), base-metal, porcelain fused to metal, andporcelain. Results: The maximum of von Mises stress in the oblique direction was higher than the vertical and horizontal directions in all conditions. In the bone-crestal section, the maximum von Mises stress (53.78 MPa) was observed in PMMA within oblique load. In FDPs, the maximum stress was generated at the connector region in all conditions. Conclusion: A noticeable difference was not observed in the bone stress distribution pattern with different prosthetic materials. Although, higher stress value could be seen in polymethyl methacrylate, all types of prosthesis yielded the same stress distribution pattern in FDP. More clinical studies are needed to evaluate the survival rate of these materials.
Experts (# of related papers)
Other Related Docs
28. Buckling Analysis of a Functionally Graded Implant Model for Treatment of Bone Fractures: A Numerical Study, ASME International Mechanical Engineering Congress and Exposition, Proceedings (IMECE) (2017)
46. Bone Loss-Related Factors in Tissue and Bone Level Dental Implants: A Systematic Review of Clinical Trials, Journal of the Korean Association of Oral and Maxillofacial Surgeons (2021)