Tehran University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
Assessment of Bioaerosol Particle Characteristics at Different Hospital Wards and Operating Theaters: A Case Study in Tehran Publisher



Bolookat F1 ; Hassanvand MS2, 3 ; Faridi S3 ; Hadei M3 ; Rahmatinia M4 ; Alimohammadi M3, 5, 6
Authors
Show Affiliations
Authors Affiliations
  1. 1. Department of Environment Engineering, Faculty of Environment & Energy, Islamic Azad University Science and Research Branch, Tehran, Iran
  2. 2. Center for Air Pollution Research, Institute for Environmental Research, Tehran University of Medical Sciences, Tehran, Iran
  3. 3. Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran
  4. 4. Student Research Committee, Department of Environmental Health Engineering, School of Public Health and safety, Shahid Beheshti University of Medical Sciences, Tehran, Iran
  5. 5. Center for Water Quality Research (CWQR), Institute for Environmental Research (IER), Tehran University of Medical Sciences, Tehran, Iran
  6. 6. Health Equity Research Center (HERC), Tehran University of Medical Sciences, Tehran, Iran

Source: MethodsX Published:2018


Abstract

This study was aimed to investigate the types and number of bacterial and fungal bioaerosols in indoor air of hospitals according to the type of wards and operating theaters. Bacterial and fungal samples were collected using the passive sampling method of 1/1/1 scheme during a six months’ period in the Khatam-Al-Anbia hospital, Tehran, Iran. A simple linear regression was used to determine the relationship between bioaerosol concentrations and the number of active beds. Bacterial bioaerosol concentrations were mainly higher than fungi in all sampling sites. A significant association was found between airborne fungal concentrations and the numbers of beds (R2 = 0.76, p < 0.05), but not observed for bacteria (R2 = 0.02, p < 0.05). Our findings provided an exposure database of airborne bacterial and fungal bioaerosol in hospital wards and operating theaters in Tehran. • Due to the importance of the exposure risk to bioaerosols for patients and medical personnel, we focused on identification of the density and diversity of bacterial and fungal bioaerosols in different wards and operating theaters.• Our results showed that the numbers of the beds have a significant effect on airborne fungal concentrations.• The results of this study can be used to set indoor air quality standards for hospital wards and operating theatres. © 2018 The Author(s)
Experts (# of related papers)
Other Related Docs
9. On the Nature of Indoor Airborne Bioaerosols at a Hospital in Iran, Journal of Air Pollution and Health (2021)
11. Health Benefits of Pm10 Reduction in Iran, International Journal of Biometeorology (2017)
25. Interventional Effect of Nanosilver Paint on Fungal Load of Indoor Air in a Hospital Ward, Canadian Journal of Infectious Diseases and Medical Microbiology (2021)