Tehran University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
Corneal Asphericity and Related Factors in the Geriatric Population: A Population-Based Study Publisher Pubmed



Hashemi H1 ; Nabovati P2 ; Aghamirsalim M3 ; Mahboubipour H4 ; Yekta A5 ; Khabazkhoob M6
Authors
Show Affiliations
Authors Affiliations
  1. 1. Noor Research Center for Ophthalmic Epidemiology, Noor Eye Hospital, Tehran, Iran
  2. 2. Department of Optometry, School of Rehabilitation Sciences, Rehabilitation Research Center, Iran University of Medical Sciences, Tehran, Iran
  3. 3. Translational Ophthalmology Research Center, Tehran University of Medical Sciences, Tehran, Iran
  4. 4. Noor Ophthalmology Research Center, Noor Eye Hospital, Tehran, Iran
  5. 5. Department of Optometry, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran
  6. 6. Department of Basic Sciences, School of Nursing and Midwifery, Shahid Beheshti University of Medical Sciences, Tehran, Iran

Source: Ophthalmic and Physiological Optics Published:2021


Abstract

Purpose: To determine the distribution of the corneal asphericity coefficient (Q value) and related factors in an Iranian geriatric population. Methods: This population-based study was conducted in 2019 in Tehran, using stratified multistage random cluster sampling. The study population was ≥60 years of age. Participants underwent corneal imaging using a Pentacam HR. Mean keratometry, corneal astigmatism, central corneal thickness, anterior chamber depth and the overall anterior and posterior Q values (for 8 mm chord diameter) were recorded. Axial length measurements were performed using the IOL Master 500. Results: 2457 eyes of 2457 individuals were analysed. The mean age was 67.3 ± 5.82 years and 1479 (60.2%) were female. The mean Q value for the anterior corneal surface was −0.35 ± 0.17 (95% CI: −0.35 to −0.34). The anterior Q value showed a statistically significant inverse relationship with axial length and mean keratometry, and a significant direct association with anterior chamber depth and corneal astigmatism. The mean posterior Q value was −0.41 ± 0.15 (95% CI: −0.42 to −0.40). The posterior Q value had a significant direct relationship with age, anterior chamber depth, mean keratometry and corneal astigmatism. Conclusion: The corneal Q values in this geriatric Iranian population were more negative than the values reported in most previous studies. Corneal asphericity was greater affected by ocular biometry and corneal curvature than demographic factors and refractive status. © 2021 The Authors Ophthalmic and Physiological Optics © 2021 The College of Optometrists