Tehran University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
Indoor Concentrations of Vocs in Beauty Salons; Association With Cosmetic Practices and Health Risk Assessment Publisher



Hadei M1 ; Hopke PK2, 3 ; Shahsavani A4, 5 ; Moradi M4 ; Yarahmadi M6 ; Emam B4 ; Rastkari N6, 7
Authors
Show Affiliations
Authors Affiliations
  1. 1. Research Center for Environmental Determinants of Health (RCEDH), Kermanshah University of Medical Sciences, Kermanshah, Iran
  2. 2. Department of Public Health Sciences, University of Rochester, School of Medicine and Dentistry, Rochester, 14642, NY, United States
  3. 3. Center for Air Resources Engineering and Science, Clarkson University, Potsdam, 13699, NY, United States
  4. 4. Environmental and Occupational Hazards Control Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
  5. 5. Department of Environmental Health Engineering, School of Public Health and Safety, Shahid Beheshti University of Medical Sciences, Tehran, Iran
  6. 6. Environmental and Occupational Health Center, Ministry of Health and Medical Education, Tehran, Iran
  7. 7. Center for Air Pollution Research (CAPR), Institute for Environmental Research (IER), Tehran University of Medical Sciences, Tehran, Iran

Source: Journal of Occupational Medicine and Toxicology Published:2018


Abstract

Background: The use of cosmetic products in beauty salons emits numerous kinds of toxic air pollutants. The objectives of this study were to measure the concentrations of benzene, toluene, ethylbenzene, xylene, formaldehyde, and acetaldehyde in 20 large beauty salons in Tehran and relate the observed concentrations to environmental and occupational characteristics of the salons. Methods: Samples were collected from inside and outside air of 20 selected salons located in different areas of the city. Several additional parameters were recorded during the sampling process including surface area, number of active employees, type of ventilation, type of ongoing treatments, temperature, humidity. Deterministic and stochastic health risk assessment of the compounds were performed. Results: Indoor concentrations of each pollutant were significantly higher than its outdoor concentrations. Health risk assessment showed that benzene, formaldehyde and acetaldehyde represent a possible cancer risk in the beauty salons. In addition, toluene, ethylbenzene, and xylene had negligible non-carcinogenic risks. Ventilation with air purifier, and fan with open window were more effective than using just a fan. Concentrations of benzene and toluene were affected by the number of hair dying treatments. The concentration of xylene was affected by the number of hair styling. The concentration of formaldehyde was affected by the number of hair styling and number of nail treatments. Conclusion: With improved ventilation and requirements for reformulated cosmetic, concentrations of toxic air pollutants in beauty salons could be reduced. © 2018 The Author(s).
Other Related Docs
12. Concentrations of Criteria Air Pollutants and Btex in Mehrabad International Airport, Journal of Mazandaran University of Medical Sciences (2018)