Tehran University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
Indoor and Outdoor Concentrations of Btex and Formaldehyde in Tehran, Iran: Effects of Building Characteristics and Health Risk Assessment Publisher Pubmed



Hadei M1 ; Hopke PK2, 3 ; Rafiee M4, 5 ; Rastkari N6 ; Yarahmadi M7 ; Kermani M8 ; Shahsavani A4, 5
Authors
Show Affiliations
Authors Affiliations
  1. 1. Center for Air Pollution Research (CAPR), Institute for Environmental Research (IER), Tehran University of Medical Sciences, Tehran, Iran
  2. 2. Department of Public Health Sciences, University of Rochester School of Medicine and Dentistry, Rochester, 14642, NY, United States
  3. 3. Center for Air Resources Engineering and Science, Clarkson University, Clarkson Ave, Potsdam, 13699-5708, NY, United States
  4. 4. Environmental and Occupational Hazards Control Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
  5. 5. Department of Environmental Health Engineering, School of Public Health, Shahid Beheshti University of Medical Sciences, Tehran, Iran
  6. 6. Center for Air pollution Research Center, Tehran University of Medical Sciences, Tehran, Iran
  7. 7. Environmental and Occupational Health Center, Ministry of Health and Medical Education, Tehran, Iran
  8. 8. Research Center for Environmental Health Technology, Iran University of Medical Sciences, Tehran, Iran

Source: Environmental Science and Pollution Research Published:2018


Abstract

BTEX (benzene, toluene, ethylbenzene, xylene) and formaldehyde are toxic compounds that can induce adverse health effect in humans. This study measured in-home and ambient concentrations of BTEX and formaldehyde across Tehran, Iran. These pollutants were sampled from the indoor and adjacent outdoor air of 45 houses (9 in each city zone) during the winter of 2015. Sampling was repeated three times for each house. The analyses were performed according to NIOSH procedures. The effect of flooring material, wall covering, ventilation system, heating system, height above ground, presence of attached garages, and distance from highways was evaluated. In addition, carcinogenic and non-carcinogenic risks of these compounds were assessed. The average indoor concentrations of benzene, toluene, ethylbenzene, xylene, and formaldehyde were 53.2, 21.5, 14.4, 21.1, and 17.9 μg/m3, respectively. The average outdoor concentrations of benzene, toluene, ethylbenzene, xylene, and formaldehyde were 43.5, 26.2, 10.0, 19.1, and 6.9 μg/m3, respectively. Separate regression models showed that wall coating, ventilation system, heating system, flat level, and distance from highways explained 29, 60, 16, 60, and 59% of the BTEX concentrations, respectively. Houses with oil painted walls and parquet flooring had higher concentrations of BTEX and formaldehyde, respectively. The health risk assessment found that the carcinogenic risks of benzene and formaldehyde exceeded 1 × 10−4 and represent a definite risk. New buildings can be designed based on the results of this study to use better materials and optimum building designs to reduce exposure to these toxic air pollutants. © 2018, Springer-Verlag GmbH Germany, part of Springer Nature.
Other Related Docs
17. Characteristics and Health Effects of Btex in a Hot Spot for Urban Pollution, Ecotoxicology and Environmental Safety (2018)
20. Levels of Formaldehyde in Residential Indoor Air of Gonabad, Iran, Human and Ecological Risk Assessment (2020)
38. The Effects of Ventilation and Building Characteristics on Indoor Air Quality in Waterpipe Cafes, Journal of Exposure Science and Environmental Epidemiology (2020)
44. Concentrations of Criteria Air Pollutants and Btex in Mehrabad International Airport, Journal of Mazandaran University of Medical Sciences (2018)
45. Formaldehyde, Encyclopedia of Toxicology# Fourth Edition: Volume 1-9 (2023)