Tehran University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
Corneal Ectasia in Mothers of Down Syndrome Children Publisher Pubmed



Hashemi H1 ; Asgari S1 ; Panahi P2 ; Mehravaran S3 ; Fotouhi A4
Authors
Show Affiliations
Authors Affiliations
  1. 1. Noor Ophthalmology Research Center, Noor Eye Hospital, No. 96 Esfandiar Blvd., Vali’asr Ave., Tehran, Iran
  2. 2. Student Research Committee, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
  3. 3. School of Computer, Mathematical, and Natural Sciences, Morgan State University, Baltimore, MD, United States
  4. 4. Department of Epidemiology and Biostatistics, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran
  5. 5. Rio de Janeiro Corneal Tomography and Biomechanics Study Group, Rio de Janeiro, RJ, Brazil
  6. 6. Department of Cornea and Refractive Surgery, Instituto de Olhos Renato Ambrosio, Rio de Janeiro, Brazil
  7. 7. Department of Opthalmology, Federal University of the State of Rio de Janeiro (UNIRIO), Rio de Janeiro, Brazil

Source: Scientific Reports Published:2021


Abstract

In this study, corneal findings regarding keratoconus (KC) and early KC among mothers with Down syndrome children (MDS) and a group of age-at-delivery-matched mothers with normal children (MNC) were compared. KC was diagnosed based on the presence of a clinical sign and at least one abnormal tomographic or biomechanical criterion. Early KC was defined as having no clinical sign in the presence of at least one abnormal tomographic or biomechanical criterion. The normal subgroups in each group were compared in terms tomographic and biomechanical parameters. In MDS and MNC, the prevalence rates were 6.5% and 1.6% for KC (P = 0.047), and 30.9% and 14.3% for early KC (P = 0.014), respectively. Comparison between the two normal subgroups showed significant differences in mean index of height asymmetry, irregularity index, anterior asphericity, pentacam random forest index, corneal stiffness parameters at first applanation, deformation amplitude ratios, integrated radius-1 mm, highest concavity deflection amplitude, biomechanical corrected IOP, peak distance, and radius (all P < 0.05). This study showed that MDS are more likely to have KC and also to have thinner, steeper and softer corneas compared to MNC. This results support the need for further work for determining the risk of delivering a child with DS. © 2021, The Author(s).