Generation of 18F-Fdg Pet Standard Scan Images From Short Scans Using Cycle-Consistent Generative Adversarial Network Publisher Pubmed



Ghafari A1 ; Sheikhzadeh P1, 2 ; Seyyedi N3 ; Abbasi M2 ; Farzenefar S2 ; Yousefirizi F4 ; Ay MR1, 5 ; Rahmim A4, 6
Authors
Show Affiliations
Authors Affiliations
  1. 1. Department of Medical Physics and Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran
  2. 2. Department of Nuclear Medicine, Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran
  3. 3. Nursing and Midwifery Care Research Center, Iran University of Medical Sciences, Tehran, Iran
  4. 4. Department of Integrative Oncology, BC Cancer Research Institute, Vancouver, BC, Canada
  5. 5. Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran
  6. 6. Departments of Radiology and Physics, University of British Columbia, Vancouver, BC, Canada

Source: Physics in Medicine and Biology Published:2022


Abstract

Objective. To improve positron emission tomography (PET) image quality, we aim to generate images of quality comparable to standard scan duration images using short scan duration (1/8 and 1/16 standard scan duration) inputs and assess the generated standard scan duration images quantitative and qualitatively. Also, the effect of training dataset properties (i.e. body mass index (BMI)) on the performance of the model(s) will be explored. Approach. Whole-body PET scans of 42 patients (41 18F-FDG and one 68Ga-PSMA) scanned with standard radiotracer dosage were included in this study. One 18F-FDG patient data was set aside and the remaining 40 patients were split into four subsets of 10 patients with different mean patient BMI. Multiple copies of a developed cycle-GAN network were trained on each subset to predict standard scan images using 1/8 and 1/16 short duration scans. Also, the models’ performance was tested on a patient scanned with the 68Ga-PSMA radiotracer. Quantitative performance was tested using peak signal-to-noise ratio (PSNR), structural similarity index (SSIM), and normalized root mean squared error (NRMSE) metrics, and two nuclear medicine specialists analyzed images qualitatively. Main results. The developed cycle-GAN model improved the PSNR, SSIM, and NRMSE of the 1/8 and 1/16 short scan duration inputs both 18F-FDG and 68Ga-PSMA radiotracers. Although, quantitatively PSNR, SSIM, and NRMSE of the 1/16 scan duration level were improved more than 1/8 counterparts, however, the later were qualitatively more appealing. SUVmean and SUVmax of the generated images were also indicative of the improvements. The cycle-GAN model was much more capable in terms of image quality improvements and speed than the NLM denoising method. All results proved statistically significant using the paired-sample T-Test statistical test (p-value < 0.05). Significance. Our suggested approach based on cycle-GAN could improve image quality of the 1/8 and 1/16 short scan-duration inputs through noise reduction both quantitively (PSNR, SSIM, NRMSE, SUVmean, and SUVmax) and qualitatively (contrast, noise, and diagnostic capability) to the level comparable to the standard scan-duration counterparts. The cycle-GAN model(s) had a similar performance on the 68Ga-PSMA to the 18F-FDG images and could improve the images qualitatively and quantitatively but requires more extensive study. Overall, images predicted from 1/8 short scan-duration inputs had the upper hand compared with 1/16 short scan-duration inputs. © 2022 Institute of Physics and Engineering in Medicine.