Isfahan University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
Do Metal Artifact Reduction Algorithms Influence the Detection of Implant-Related Injuries to the Inferior Alveolar Canal in Cbct Images? Publisher Pubmed



Soltani P1, 2 ; Devlin H3, 4 ; Etemadi Sh M5 ; Rengo C2 ; Spagnuolo G2, 6 ; Baghaei K7
Authors
Show Affiliations
Authors Affiliations
  1. 1. Department of Oral and Maxillofacial Radiology, Dental Implants Research Center, Dental Research Institute, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran
  2. 2. Department of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples “Federico II”, Naples, Italy
  3. 3. The Dental School, The University of Bristol, Bristol, United Kingdom
  4. 4. Department of Restorative Dentistry, School of Dentistry, Jordan University, Amman, Jordan
  5. 5. Department of Oral and Maxillofacial Surgery, Dental Implants Research Center, Dental Research Institute, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran
  6. 6. Therapeutic Dentistry Department, Institute for Dentistry, Sechenov University, Moscow, 119991, Russian Federation
  7. 7. Student Research Committee, School of Dentistry, Isfahan University of Medical Sciences, Hezar- Jarib Ave, Isfahan, Iran

Source: BMC Oral Health Published:2024


Abstract

Background: The routine application of dental implants for replacing missing teeth has revolutionized restorative and prosthetic dentistry. However, cone beam computed tomography (CBCT) evaluations of structures adjacent to the implants are limited by metal artifacts. There are several methods for reducing metal artifacts, but this remains a challenging task. This study aimed to examine the effectiveness of metal artifact reduction (MAR) algorithms in identifying injuries of implants to the inferior alveolar canal in CBCT images. Method: In this in vitro study, mono-cortical bone windows were created and the inferior alveolar canal was revealed. Using 36 implants, pilot drill and penetration damage of the implant tip into the canal was simulated and compared to the control implants with distance from the canal. CBCT images were evaluated by four experienced observers with and without the MAR algorithm and compared to direct vision as the gold standard. The values of accuracy, sensitivity, and specificity were obtained and compared by receiver operating characteristic (ROC) curve (α = 0.05). Result: The area under the ROC curve values for detection of pilot drill injuries varied between 0.840–0.917 and 0.639–0.854 in the active and inactive MAR conditions, respectively. The increase in ROC area was only significant for one of the observers (P = 0.010). For diagnosing penetrative injuries, the area under the ROC curve values was between 0.990–1.000 and 0.722–1.000 in the active and inactive MAR conditions, respectively. The improvement of ROC curve values in active MAR mode was only significant for one of the observers (P = 0.006). Conclusion: Activation of MAR improved the diagnostic values of CBCT images in detecting both types of implant-related injuries to the inferior alveolar canal. However, for most observers, this increase was not statistically significant. © The Author(s) 2024.
Experts (# of related papers)
Other Related Docs
12. Accuracy of Tooth-Implant Impressions: Comparison of Five Different Techniques, Clinical and Experimental Dental Research (2023)
30. Bone Loss-Related Factors in Tissue and Bone Level Dental Implants: A Systematic Review of Clinical Trials, Journal of the Korean Association of Oral and Maxillofacial Surgeons (2021)