Tehran University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
Accuracy of Digital Impression Taking Using Intraoral Scanner Versus the Conventional Technique Publisher



Zarbakhsh A1 ; Jalalian E1 ; Samiei N2 ; Mahgoli MH3 ; Ghane HK1
Authors
Show Affiliations
Authors Affiliations
  1. 1. Department of Prosthodontics, Dental Branch, Azad University, Tehran, Iran
  2. 2. Department of Periodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
  3. 3. School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran

Source: Frontiers in Dentistry Published:2021


Abstract

Objectives: Intraoral scanners have shown promising results when used as an adjunct or alternative to conventional impression techniques. This study compared the accuracy of digital impression taking using an intraoral scanner versus the conventional technique. Materials and Methods: In this in-vitro experimental study, a typodont molar tooth was prepared as the standard model and scanned by TRIOS intraoral scanner. Ten digital impressions were fabricated as such and intraoral scans were sent to the manufacturers. In the conventional method, using addition silicone impression material, a stone die was fabricated. Using a computer-aided design/computer-aided manufacturing scanner, the die was scanned, and the data were transferred to the software. After the fabrication of frameworks, the replica technique was used. The replicas’ thickness (indicative of the gap between the framework and the model and the accuracy of impression taking) was 12 points. The data were analyzed using student's t-test. Results: The mean thickness of replicas (gap between the internal surface of frameworks and the standard model) at the three points in the buccal, lingual, mesial, and distal sections in the digital impression technique was lower than that in the conventional technique (P<0.0001). In other words, the accuracy of impressions taken by the digital method was significantly higher than those taken by the conventional method. Conclusion: Intraoral digital scanner had significantly higher accuracy than the conventional method in all points. Thus, the digital method can be reliably used as an adjunct or alternative to the conventional method to increase the accuracy of impression taking. © 2021, Tehran University of Medical Sciences. All rights reserved.
Experts (# of related papers)