Isfahan University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
The Magnitude of Errors Associated in Measuring the Loads Applied on an Assistive Device While Walking Publisher



Karimi M1 ; Jamshidi N2
Authors
Show Affiliations
Authors Affiliations
  1. 1. Rehabilitation Engineering Research Center, Isfahan University of Medical Sciences, Isfahan, Iran
  2. 2. Department of Biomedical Engineering, University of Isfahan, HezarJerib St, Isfahan, Iran

Source: Journal of Medical Signals and Sensors Published:2012


Abstract

Measurement of the loads exerted on the limb is a fundamental part of designing of an assistive device, which has been done by using strain gauges or a transducer. Although calculation of loads applied on an orthosis coefficients achieved from calibration is a standard way, most of researchers determined the loads based on available equations. Therefore, the aim of this research is finding the accuracy of this method with respect to calibration. Some strain gauges were attached on the lateral bar of a reciprocal gait orthosis. It was calibrated for axial force and the anteroposterior and mediolateral moments. The outputs of strain gauge were changed to force, and moments based on the coefficients were achieved from calibration using available equations, while 5 normal subjects were walking with the orthosis. There was a significant difference between the force and moments exerted on the orthosis during walking based on the two methods (mostly extension moment and compression force). The results of this research indicated that the output of strain gauge varies based on the methods of calculation. As calibration the gauge is a standard method, it is recommended to calibrate it before use.
Other Related Docs
9. Centre of Pressure Characteristics in Normal, Planus and Cavus Feet, Journal of Foot and Ankle Research (2018)
10. Balance and Gait Performance of Scoliotic Subjects: A Review of the Literature, Journal of Back and Musculoskeletal Rehabilitation (2016)
16. Evaluation of Joint Contact Forces in Subjects With Knee Osteoarthritis, Muscles, Ligaments and Tendons Journal (2022)
18. Influence of Foot Insole on the Gait Performance in Subjects With Flat Foot Disorder, Journal of Mechanics in Medicine and Biology (2019)
19. The Effects of Scoliosis on Spinal Muscles Length and Joint Contact Forces, Journal of Mechanics in Medicine and Biology (2018)
20. Kinematic Analysis of Walking With Scottish Rite Orthosis, Lecture Notes in Electrical Engineering (2014)
23. Pistoning Assessment in Lower Limb Prosthetic Sockets, Prosthetics and Orthotics International (2012)
24. Gait Modeling for Assessment of Ankle-Foot Orthosis, 2008 Cairo International Biomedical Engineering Conference, CIBEC 2008 (2008)
30. Differences in Center of Pressure Trajectory Between Normal and Steppage Gait, Journal of Research in Medical Sciences (2010)
33. What Are the Next Steps in Designing an Orthosis for Paraplegic Subjects?, International Journal of Preventive Medicine (2012)
36. Scoliosis Curve Analysis With Milwaukee Orthosis Based on Open Simm Modeling, Journal of Craniovertebral Junction and Spine (2015)
37. The Influence of Foot Hyperpronation on Pelvic Biomechanics During Stance Phase of the Gait: A Biomechanical Simulation Study, Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine (2018)
38. Gait Analysis of Walking With Scottish Rite Orthosis, 2014 2nd RSI/ISM International Conference on Robotics and Mechatronics, ICRoM 2014 (2014)