Isfahan University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
Application of Anodized Titanium for Enhanced Recruitment of Endothelial Progenitor Cells Publisher



Moradi I1 ; Behjati M2 ; Kazemi M3
Authors
Show Affiliations
Authors Affiliations
  1. 1. Nanotechnology Consultancy and Development Center (NCDC), Padova 35127, Via Svizzera 16, Italy
  2. 2. Department of Cardiology, Isfahan University of Medical Sciences, Isfahan 8174673461, Iran
  3. 3. Isfahan University of Medical Sciences, Isfahan 8174673461, Iran

Source: Nanoscale Research Letters Published:2012


Abstract

Objectives To study the efficacy of an effective anodized titanium surface with enhanced attachment of endothelial progenitor cell (EPC). Background In-stent restenosis is a major obstacle for vascular patency after catheter-based intravascular interventions. Recently, stents that capture EPCs have been paid attention in order to make a functional endothelialized layer at the site of stent-induced endothelial denudation. Anodized titanium has been shown to enhance stem cell attachment. Anodization is a quick and inexpensive method, which can provide suitable stent surface. Methods Surface topography was examined by high-resolution scanning electron microscopy (SEM). Substrates were co-cultured with EPCs at second passage in 24-well culture plates. Evaluation of cell growth, proliferation, viability, surface cytotoxicity and cell adhesion was performed using 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) test and 4,6-diamidino-2-phenylindole dihydrochloride staining. For platelet attachment, platelets added to substrates were evaluated under SEM. Results The average MTT values for tissue culture polystyrene plate, unanodized and anodized titanium with nanostructure were equal to 0.49, 0.16 and 0.72, respectively (P < 0.05). The surface had no cytotoxic effects on cells. The average cell attachment results showed that 9,955 ± 461.18, 3,300 ± 197.98 and 11,359 ± 458.10 EPCs were attached per well of tissue culture polystyrene plate, unanodized and anodized titanium surfaces, respectively (P < 0.05). Conclusions Anodized titanium surfaces can be potentially applied for devices that need enhanced recruitment of EPCs. This unique property makes these anodized surfaces good and cheap candidates for designing cardiovascular medical devices as endovascular stents. © 2012 Moradi et al.