Spinning Slithole Collimation for High-Sensitivity Small Animal Spect: Design and Assessment Using Gate Simulation Publisher Pubmed



Mahani H1, 2 ; Raisali G1 ; Kamaliasl A3 ; Ay MR2, 4
Authors
Show Affiliations
Authors Affiliations
  1. 1. Radiation Application Research School, Nuclear Science and Technology Research Institute, Tehran, Iran
  2. 2. Research Center for Molecular and Cellular Imaging, Tehran University of Medical Science, Tehran, Iran
  3. 3. Radiation Medicine Department, Shahid Beheshti University, Tehran, Iran
  4. 4. Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Science, Tehran, Iran

Source: Physica Medica Published:2017


Abstract

Purpose While traditional collimations are widely used in preclinical SPECT imaging, they usually suffer from possessing a low system sensitivity leading to noisy images. In this study, we are aiming at introducing a novel collimator, the slithole, offering a superior resolution-sensitivity tradeoff for small animal SPECT. Methods The collimator was designed for a molecular SPECT scanner, the HiReSPECT. The slithole is a knife-edge narrow long aperture extended across long-axis of the camera's head. To meet the data completeness requirement, the collimator-detector assembly spins at each regular SPECT angle. The collimator was modeled within GATE Monte Carlo simulator and the data acquisition was performed for NEMA Image Quality (IQ) phantom. In addition, a dedicated 3D iterative reconstruction algorithm based upon plane-integral projections was also developed. Results The mean sensitivity of the slithole is 285 cps/MBq while the current parallel-hole collimator holds a sensitivity of 36 cps/MBq at a 30 mm distance. The slithole collimation gives rise to a tomographic resolution of 1.8 mm compared to a spatial resolution of ∼1.7 mm for the parallel-hole one (even after resolution modeling). A 1.75 reduction factor in the noise level was observed when the current parallel-hole collimator is replaced by the slithole. Furthermore, quantitative analysis proves that 3 full-iterations of our dedicated image reconstruction lead to optimal image quality. For the largest rod in the NEMA IQ phantom, a recovery coefficient of ∼0.83 was obtained. Conclusion The slithole collimator outperforms the current parallel-hole collimation by exhibiting a better resolution-sensitivity compromise for preclinical SPECT studies. © 2017 Associazione Italiana di Fisica Medica