Tehran University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
Reduced Fluence Corneal Cross-Linking in Mild to Moderate Keratoconus: One Year-Follow-Up Publisher Pubmed



Ghaffari SR1 ; Khaheshi S1 ; Alipour F1 ; Mashhadi Farahani S1 ; Beheshtnejad AH1 ; Hafezi F2, 3, 4
Authors
Show Affiliations
Authors Affiliations
  1. 1. Eye Research Center, Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran
  2. 2. Department of Ophthalmology, Geneva University Hospitals, Geneva, Switzerland
  3. 3. ELZA Institute, Dietikon, Switzerland
  4. 4. Department of Ophthalmology, University of Wenzhou, Wenzhou, China

Source: European Journal of Ophthalmology Published:2021


Abstract

Purpose: To evaluate the safety and efficacy of reduced fluence CXL (lower dose of UV-A irradiation) in mild to moderate keratoconus. Setting: Farabi Eye Hospital, Tehran, Iran. Design: Non-randomized prospective comparative interventional case series. Every eligible patient included in the study (mild to moderate progressive keratoconus) was randomly allocated to case (reduced fluence) and control (standard) groups, except for bilateral patients. In these patients the eye with more advanced disease was allocated to control group and the other eye was randomly assigned in either case or control group. Operators performing refraction and images and the data analyst were masked, but patients and physicians were not. Methods: Forty-six eyes of 38 patients were recruited. Group 1 received 7 min (fluence of 3.8 J/cm2), while group 2 received 10 min of 9 mW/cm2 UV-A (fluence of 5.4 J/cm2). Visual, keratometric and biomechanical outcomes were compared between groups. Results: At last follow-up (mean12 months, range 6–24 months), there were no statistically significant differences in changes in uncorrected visual acuity, best corrected distance visual acuity, Kmax, Kmean, corneal hysteresis, corneal resistance factor, endothelial cell counts, demarcation line depth, and intraoperative pain scores between groups (all p-values < 0.05). Conclusion: The results of this study show comparable one-year outcomes between 3.8 and 5.4 J/cm2 accelerated CXL in mild to moderate keratoconus. Should the results of this study be confirmed in longer follow-ups, using a reduced fluence setting could be considered as an alternative to standard treatment in these patients. © The Author(s) 2020.
Related Docs
2. Updates on Managements for Keratoconus, Journal of Current Ophthalmology (2018)
Experts (# of related papers)