Isfahan University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
Comparison of Applanation Tonometry With and Without Fluorescein



Bamdad S1 ; Roozbahani M2 ; Rouzbahani R3 ; Nazarian S4 ; Ghaffarian H4
Authors
Show Affiliations
Authors Affiliations
  1. 1. Department of Ophthalmology, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
  2. 2. Department of Ophthalmology, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran
  3. 3. Isfahan University of Medical Sciences, Isfahan, Iran
  4. 4. Yasooj University of Medical Sciences, Yasooj, Iran

Source: Journal of Isfahan Medical School Published:2011

Abstract

Background: Tonometry is one of the important parts of ocular examination. It has been estimated that more than 900000 people in the United State have visual problems due to glaucoma; however most of them are not aware of their disease. Goldmann applanation tonometry is the most common, accurate, and the gold standard method for intraocular pressure (IOP) measurement. Having considered the complications of using fluorescein, such as burning sensation, allergic reaction, pruritus, and infection, as well as its high costs and less availability, we compared Goldmann applanation tonometry with and without flourescein usage. Methods: In this study, we evaluated 250 patients (500 eyes) referred to Mofateh clinic, Yasuj, Iran in May 2008. Patients with glaucoma, sunken eyes, and narrow palperbral fissure as well as those younger than 15 years old and non-cooperative patients were excluded from this study. Tonometry of one eye for each patient was done randomly with flourescein and the other without it. Finding: 105 women (42%) and 142 men (58%) with mean age of 32 ± 13 years were enrolled in this study. The mean IOP with and without flourescein were 12.90 ± 2.07 and 12.60 ± 2.09 mmHg, respectively. The mean IOP of right eyes was 13.08 ± 1.73 mmHg with flourescein and 12.68 ± 2.11 mmHg without flourescein. The mean IOP in left eyes was 13.12 ± 2.04 mmHg with flourescein and 12.12 ± 2.33 mmHg without flourescein. Conclusion: There are not any statistically significant differences between IOP measurement with and without flourescein. Further investigations are recommended in this regard.
Other Related Docs
11. Iolmaster Versus Manual Keratometry After Photorefractive Keratectomy, Journal of Ophthalmic and Vision Research (2011)
14. Relation Between Intraocular Pressure and Duration of Diabetes, Journal of Isfahan Medical School (2015)
21. A Double Blind Clinical Trial on the Efficacy of Honey Drop in Vernal Keratoconjunctivitis, Evidence-based Complementary and Alternative Medicine (2014)
23. Diagnostic Accuracy of Imaging Devices in Glaucoma: An Updated Meta-Analysis, Medical Journal of the Islamic Republic of Iran (2023)
35. Topiramate and the Vision: A Systematic Review, Clinical Ophthalmology (2012)
42. Impairment of Lacrimal Drainage After Cataract Surgery, Journal of Research in Medical Sciences (2007)
44. Convergence Insufficiency in the Geriatric Population, Optometry and Vision Science (2021)
46. Effects of Propranolol in Patients With Central Serous Chorioretinopathy, Journal of Research in Medical Sciences (2008)
47. Changes in Intraocular Pressure After Exercise Test, Oman Journal of Ophthalmology (2017)