Tehran University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
Determination of the Biomarker L-Tryptophan Level in Diabetic and Normal Human Serum Based on an Electrochemical Sensing Method Using Reduced Graphene Oxide/Gold Nanoparticles/18-Crown-6 Publisher Pubmed



Khoshnevisan K1, 2 ; Torabi F3 ; Baharifar H4 ; Sajjadijazi SM2, 5 ; Afjeh MS2 ; Faridbod F6 ; Larijani B2 ; Khorramizadeh MR1, 2, 7
Authors
Show Affiliations
Authors Affiliations
  1. 1. Biosensor Research Center, Endocrinology & Metabolism Molecular-Cellular Sciences Institute, Tehran University of Medical Sciences, Tehran, 1411713137, Iran
  2. 2. Endocrinology and Metabolism Research Center, Endocrinology and Metabolism Clinical Sciences Institute, Tehran University of Medical Sciences, Tehran, 1411713137, Iran
  3. 3. School of Chemistry, College of Science, University of Tehran, Tehran, 1417466191, Iran
  4. 4. Department of Medical Nanotechnology, Applied Biophotonics Research Center, Science and Research Branch, Islamic Azad University, Tehran, 1477893855, Iran
  5. 5. Cell Therapy and Regenerative Medicine Research Center, Endocrinology and Metabolism Molecular-Cellular Sciences Institute, Tehran University of Medical Sciences, Tehran, 1411713137, Iran
  6. 6. Center of Excellence in Electrochemistry, School of Chemistry, College of Science, University of Tehran, Tehran, 1417466191, Iran
  7. 7. Zebrafish Core Facility, Endocrinology and Metabolism Research Institute, Tehran University of Medical Sciences, Tehran, 1411713137, Iran

Source: Analytical and Bioanalytical Chemistry Published:2020


Abstract

A novel nanocomposite-modified electrode based on reduced graphene oxide (rGO) decorated with 18-crown-6 (Cr.6) and gold nanoparticles (GNPs) on the surface of a glassy carbon electrode (GCE) was successfully fabricated to investigate the electrochemical sensing of the biomarker L-tryptophan (L-Trp) in the presence of dopamine (DA), ascorbic acid (AA), urea, and glucose. The rGO-GNPs-Cr.6/GCE displayed high electrochemical catalytic activity for L-Trp determination using square-wave voltammetry (SWV). The electrochemical behavior of L-Trp at the rGO-GNPs-Cr.6/GCE displayed higher oxidation current and potential (oxidation peak current of 40 μA at 0.85 V) than rGO-GNPs/GCE, Cr.6/GCE, GNPs/GCE, rGO/GCE, and bare GCE. The SWV demonstrated a linear range of L-Trp concentration from 0.1 to 2.5 μM. A low limit of detection (LOD) was found for L-Trp, with LOD of about 0.48 μM and 0.61 μM in diabetic and normal serum, respectively. The fabricated sensor demonstrated high selectivity and sensitivity, and good stability and reproducibility for L-Trp sensing. Finally, the nanocomposite (rGO-GNPs-Cr.6)-modified GCE was applied for the determination of L-Trp in normal and diabetic human serum samples, and displayed excellent LOD and recoveries higher than 91.8%. [Figure not available: see fulltext.] © 2020, Springer-Verlag GmbH Germany, part of Springer Nature.