Tehran University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
Design and Fabrication of Electrochemical Biosensor Based on Nano-Graphene to Detect Serotonin in Diabetic Zebra Fish



Khoshnevisan K1 ; Sajjadijazi SM2, 3 ; Faridbod F4 ; Larijani B2 ; Khorramizadeh MR1
Authors
Show Affiliations
Authors Affiliations
  1. 1. Biosensor Research Center, Endocrinology& Metabolism Molecular-Cellular Sciences Institute, Tehran University of Medical Sciences, Tehran, Iran
  2. 2. Endocrinology and Metabolism Research Center, Endocrinology and Metabolism Clinical Sciences Institute, Tehran University of Medical Sciences, Tehran, Iran
  3. 3. Cell Therapy and Regenerative Medicine Research Center, Endocrinology and Metabolism Molecular-Cellular Sciences Institute, Tehran University of Medical Sciences, Tehran, Iran
  4. 4. School of Chemistry, College of Science, University of Tehran, Tehran, Iran

Source: Iranian Journal of Diabetes and Metabolism Published:2020

Abstract

Background: A novel nanocomposite-modified electrode based on reduced graphene oxide (rGO) decorated with crown-ether and gold nanoparticles (GNPs) on the surface of a glassy carbon electrode (GCE) was fabricated to investigate 5-HT determination. Methods: The morphology of nanocomposite was characterized by scaning electron microscopy (SEM). Diabetic zebrafish was obtained by overfeeding via glucose. 5-HT was successfully determined in the presence of dopamine (DA), ascorbic acid (AA), urea, glucose, and L-tryptophan (L-Trp) by using electrochemical methods. Results: The nanocomposite exhibited satisfactory electrochemical catalytic activity for 5-HT determination using square-wave voltammetry (SWV). The electrochemical behavior of 5-HT at the nanocomposite/GCE displayed reasonable oxidation current and potential. The limit of detection (LOD) of 5-HT obtained from the real samples, containing the control and diabetic group by using the proposed system and HPLC method, was calculated to be about 0.3 and 0.1 µg/L, respectively. The prposed system also demonstrated high selectivity, reasonable sensitivity, and good stability and reproducibility for 5-HT sensing. The nanocomposite was applied for the determination of the biomarker 5-HT in the diabetic and control groups of zebrafish and displayed excellent recoveries about 93 and low relative error about 3% while compared with standard method. Conclusions: It seems that the 5-HT level can be used for earlier diagnosis of diabetes. © 2020, Tehran University of Medical Sciences. All rights reserved.