Isfahan University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
Determination of Gamma Camera’S Calibration Factors for Quantitation of Diagnostic Radionuclides in Simultaneous Scattering and Attenuation Correction Publisher Pubmed



Asgari A1 ; Ashoor M1 ; Sarkhosh L1 ; Khorshidi A2 ; Shokrani P3
Authors
Show Affiliations
Authors Affiliations
  1. 1. Nuclear Science and Technology Research Institute, AEOI, P.O. Box: 113653486, Tehran, Iran
  2. 2. School of Paramedical, Gerash University of Medical Science, P.O. Box: 7441758666, Gerash, Iran
  3. 3. Isfahan University of Medical Sciences, P.O. Box: 8174673461, Isfahan, Iran

Source: Current Radiopharmaceuticals Published:2019


Abstract

Objective: The characterization of cancerous tissue and bone metastasis can be distinguished by accurate assessment of accumulated uptake and activity from different radioisotopes. The various parameters and phenomena such as calibration factor, Compton scattering, attenuation and penetration intrinsicallyinfluence calibration equation, and the qualification of images as well. Methods: The camera calibration factor (CF) translates reconstructed count map into absolute activity map, which is determined by both planar and tomographic scans using different phantom geometries. In this study, the CF for radionuclides of Tc-99m and Sm-153 in soft tissue and bone was simulated by the Monte Carlo method, and experimental results were obtained in equivalent tissue and bone phantoms. It may be employed for the simultaneous correction of the scattering and attenuation rays interacted with the camera, leading to corrected counts. Also, the target depth (d) may be estimated by a combination of scattering and photoelectric functions, which we have published before. Results: The calibrated equations for soft tissue phantom for the radionuclides were obtained by RTc =-10d+ 300 and RSm =-8d + 100, and the relative errors between the simulated and experimental results were 4.5% and 3.1%, respectively. The equations for bone phantom were RTc =-30d + 300 and RSm =-10d + 100, and the relative errors were 5.4% and 5.6%. The R and d are in terms of cpm/mCi and cm. Besides, the collimators' impact was evaluated on the camera response, and the relevant equations were obtained by the Monte Carlo method. The calibrated equations as a function of various radiation angles on the center of camera's cells without using collimator indicated that both sources have the same quadratic coefficient by-2E-08 and same vertical width from the origin by 8E-05. Conclusion: The presented procedure may help determine the absorbed dose in the target and likewise optimize treatment planning. © 2019 Bentham Science Publishers.
Other Related Docs
21. Monte Carlo Study of Fetal Dosimetry Parameters for 6 Mv Photon Beam, Journal of Medical Signals and Sensors (2013)