Tehran University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
The Measurement of Hazardous Biogenic Amines in Non-Alcoholic Beers: Efficient and Applicable Miniaturized Electro-Membrane Extraction Joined to Gas Chromatography-Mass Spectrometry Publisher



Kamankesh M1, 2 ; Barzegar F3 ; Shariatifar N4 ; Mohammadi A3, 5
Authors
Show Affiliations
Authors Affiliations
  1. 1. Food Safety Research Center (Salt), Semnan University of Medical Sciences, Semnan, 35147-99442, Iran
  2. 2. School of Pharmacy, Semnan University of Medical Sciences, Semnan, 35147-99442, Iran
  3. 3. Department of Food Science and Technology, Faculty of Nutrition Science, Food Science and Technology/National Nutrition and Food Technology Research Institute, Shahid Beheshti University of Medical Sciences, Tehran, 198396-3113, Iran
  4. 4. Department of Environmental Health, Food Safety Division, School of Public Health, Tehran University of Medical Sciences, Tehran, 14176-13151, Iran
  5. 5. Food Safety Research Center, Shahid Beheshti University of Medical Sciences, Tehran, 198396-3113, Iran

Source: Foods Published:2023


Abstract

The determination of biogenic amines (BAs) as serious food contaminants and chemical indicators of unwanted microbial contamination or deficient processing conditions in non-alcoholic beers is of great interest for the beverage industries. In the present investigation, the combination of hollow fiber-electro-membrane extraction (HF-EME) and dispersive liquid–liquid microextraction (DLLME) followed by gas chromatography-mass spectrometry (GC/MS) was applied for the analysis of histamine, putrescine, tyramine, cadaverine in non-alcoholic beers. EME is fundamentally based on the electrostatic attraction, diffusion and solvability of analytes in a selected acceptor phase. This membrane-based extraction technique promoted selectivity and the enrichment factor. The DLLME process reduced the volumes of organic solvents and make the coupling of HF-EME to the CG/MS conceivable. The leading variables, which have a great effect on extraction recovery, were optimized. The relative standard deviation was achieved between 4.9 and 7.0%. The recoveries were between 94% and 98%. The limit of detection and limit of quantification were found to be 0.92–0.98 ng mL−1 and 3.03–3.23 ng mL−1, respectively. The enrichment factor was calculated in the range 36–41. The achievements revealed that putrescine and tyramine, with concentrations of 3.87 and 2.33 µg g−1, were at the highest concentration in non-alcoholic beers. This offered method with great benefits could help beverage industries to monitor the concentration of BAs in beers and control them. © 2023 by the authors.