Tehran University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
Electrochemical Immunosensor for Determination of Cardiac Troponin I Using Two-Dimensional Metal-Organic Framework/Fe3o4–Cooh Nanosheet Composites Loaded With Thionine and Pctab/Des Modified Electrode Publisher



Ahmadi A1, 2 ; Khoshfetrat SM3 ; Mirzaeizadeh Z1 ; Kabiri S1, 2 ; Rezaie J2 ; Omidfar K1, 2
Authors
Show Affiliations
Authors Affiliations
  1. 1. Biosensor Research Center, Endocrinology and Metabolism Molecular–Cellular Sciences Institute, Tehran University of Medical Sciences, Tehran, Iran
  2. 2. Endocrinology and Metabolism Research Center, Endocrinology and Metabolism Research Institute, Tehran University of Medical Sciences, Tehran, Iran
  3. 3. Chemistry Department, Faculty of Science, Ayatollah Boroujerdi University, Boroujerd, Iran

Source: Talanta Published:2022


Abstract

Cardiac troponin-I (CTnI) is one of the most popular biomarkers which can be utilized for the diagnosis and control of acute myocardial infarction in clinical practice. Here, a sandwich-type electrochemical immunosensor has been established using the zinc-based metal-organic framework/Fe3O4–COOH/thionine labeled anti-CTnI monoclonal antibody (Ab1-Zn-MOF/Fe3O4–COOH/Thi) nanocomposite as signaling molecule and a polymer film of cetyltrimethylammonium bromide (pCTAB) in the presence of choline chloride-urea deep eutectic solvent (DES) and anti-CTnI polyclonal antibody (Ab2) as immobilization substance of detecting surface. The porous ultrathin layers of Zn-MOF nanosheets successfully prepare a well-defined structure for Fe3O4–COOH electrocatalyst and Thi within a certain two dimensional (2D) regions, which enhances electrochemical reduction of Thi. The Ab1-Zn-MOF/Fe3O4–COOH/Thi nanocomposites were introduced to CTnI in the specimen and on the surface of pCTAB/DES-Au-SPE quantitative determination of CTnI was achieved using differential pulse voltammetry after sandwiching the CTnI target between Ab1-nanocomposite and Ab2 which was encapsulated into the pCTAB/DES-Au-SPE. This immunosensor indicated the appropriate assay performance for CTnI with the detection range of 0.04 ng mL−1 to 50 ng mL−1 and the limit of detection of 0.0009 ng mL−1. This study provides convenient plan for sensitive detection of bioanalytes and opens a path for the establishment of user-friendly and cost-effective device. © 2021 Elsevier B.V.
Other Related Docs