Evaluation of Cumulative Kidney Activity in Pediatric Nuclear Scan of the Bladder Using Conjugate View Method and Four Different Techniques for Correcting Background Radiations



Salamat MR1 ; Ebrahimi A1 ; Moslehi M1
Authors
Show Affiliations
Authors Affiliations
  1. 1. Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran

Source: Tehran University Medical Journal Published:2021

Abstract

Background: At present, in nuclear medicine to calculate the cumulative activity of various organs, different techniques are being used to correct the background radiations in the conjugate view method. Each of these techniques considers the effect and weight of background radiations to a different extent. These background radiations can cause errors in cumulative activity calculations. The purpose of this study was to evaluate and compare different techniques of correcting background radiations to each other in calculating kidney cumulative activity during the nuclear scan of the bladder in children. Methods: This study was Cross-sectional and performed for patients who were referred to Isfahan Shahid Chamran Hospital between December 2019 and June 2020. In this study using Foley, 1 mCi of TC-DTPA radio-pharmaceutical that was diluted with normal saline was injected into the patient's bladder, then images recorded by gamma cameras were extracted at 2, 5, 10, and 20 minutes, Finally with ROI drawing around kidney with having vesicoureteral reflux, Cumulative renal activity was calculated with four correcting background radiations techniques such as without correction of background radiation, conventional method, Buijs method, and Kojima method Eventually, the data was Eventually, the data was compared to each other to determine how much weight each of these techniques consider for background radiations. Results: Cumulative kidney activity after calculation with four correcting background radiations techniques such as without correction of background radiation, conventional method, Buijs method, and Kojima method were 14.970±4.776, 13.544±4.357, 13.885±4.451, 13.879±4.449 mCi.min. respectively After comparing the calculated cumulative activity without correcting the background radiations with the cumulative activity calculated by the three techniques of correcting the background radiations such as the conventional method, Buijs method, and Kojima method, the value (P<0.05) was obtained in all cases, which shows that elimination of background radiations is significantly meaningful in the calculations of cumulative activity in the conjugate method for nuclear exams Conclusion: after comparing correcting background radiations techniques to each other, it was determined that the conventional method technique considers the effect and weight of background radiations more than the two other techniques such as the Buijs method and Kojima method in cumulative activity calculations. Copyright © 2021 Salamat et al. Tehran University of Medical Sciences. Published by Tehran University of Medical Sciences.
Experts (# of related papers)
Other Related Docs
17. Patient Dose Resulting From Ct Examinations in Yazd, Iran, Iranian Journal of Radiation Research (2006)
24. Conventional and Spiral Ct Dose Indices in Yazd General Hospitals, Iran, Iranian Journal of Radiation Research (2006)
32. Children, Ct Scan and Radiation, International Journal of Preventive Medicine (2010)
34. Dose Response Evaluation of a Low Density Anoxic Polymer Gel Dosimeter Using Mri, International Journal of Radiation Research (2015)
45. Evaluation of Radiographers' and Ct Technologists' Knowledge Regarding Ct Exposure Parameters, Polish Journal of Medical Physics and Engineering (2019)