Tehran University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share this content! On (X network) By
Simultaneous Electrochemical Determination of Isoniazid and Ethambutol Using Poly-Melamine/Electrodeposited Gold Nanoparticles Modified Pre-Anodized Glassy Carbon Electrode Publisher



Sepehri Z1 ; Bagheri H2 ; Ranjbari E3 ; Amiriaref M3 ; Amidi S4 ; Rouini MR3 ; Ardakani YH3
Authors
Show Affiliations
Authors Affiliations
  1. 1. Department of Internal Medicine, Zabol University of Medical Sciences, Zabol, Iran
  2. 2. Chemical Injuries Research Center, Baqiyatallah University of Medical Sciences, Tehran, Iran
  3. 3. Biopharmaceutics and Pharmacokinetics Division, Department of Pharmaceutics, Faculty of Pharmacy, Tehran University of Medical Sciences, Tehran, 141556451, Iran
  4. 4. Department of Medicinal Chemistry, School of Pharmacy, Shahid Beheshti University of Medical Sciences, Tehran, Iran

Source: Ionics Published:2018


Abstract

For the first time, simultaneous voltammetric determination of two kinds of the first-line categorized anti-tuberculosis drugs including isoniazid (INZ) and ethambutol (EBL) was reported at a highly sensitive electrochemical sensor. The proposed sensor was successfully prepared based on an electroactive poly-melamine film and electrodeposited gold nanoparticles (PMel-Aunano)-modified pre-anodized glassy carbon electrode (GCE*). The morphological and electrochemical characteristics of the sensing surface (PMel-Aunano/GCE*) was well-characterized by scanning electron microscopy (SEM), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). The PMel-Aunano/GCE* exhibited strongly catalytic activity toward the oxidation of INZ (0.39 V potential shift) and EBL (0.29 V potential shift) in comparison with PMel/GCE* and bare GCE. Differential pulse voltammograms of INZ and EBL depicted the linear responses with their concentrations at the ranges of 0.3 to 170.0 μM and 0.5 to 150.0 μM, respectively. The detection limits for INZ and EBL were sequentially estimated as 0.08 and 0.21 μM. Furthermore, the developed electrochemical sensor was successfully implemented for the determination of INZ and EBL in real samples using standard addition method. This fabricated sensor showed to be promising for INZ and EBL detection with many desirable features including high-sensitivity, low detection limit, decrease in over-voltage, reproducible responses, and acceptable anti-interferences ability. © 2017, Springer-Verlag GmbH Germany.